![Tvone Magenta MultiView 2211045-02 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/tvone/magenta-multiview-2211045-02/magenta-multiview-2211045-02_quick-start-manual_1183536007.webp)
Mini Dense Pack Power Supply
5
Setup and Installation
Setup
1.
Install the unit as a desktop or rack mount (with optional
rack mount kit).
2.
Ensure unit has adequate ventilation around it.
3.
Plug AC cord into corresponding AC mains outlet.
4.
Connect 5VDC and/or 12VDC devices using supplied 3
position captive screw connectors. Both 5VDC and 12VDC
voltages may be used simultaneously. No internal
configurations are necessary.
Observe proper polarity when connecting devices.
Reversing polarities or connecting to the wrong voltage may
damage the Mini Dense Pack and or the attached device.
Generally, the positive (+) conductor has a white line.
Always verify plus/minus cable conductors before
connection to the Mini Dense Pack.
Total output power capacity is over 100 Watts and each port can
provide power up to the following levels:
12 Volts DC @ 700 mA (8.4W)
5 Volts DC @ 1.67 A (8.35W).
Up to 100 watts of power can be supplied by any combination of
ports so long as the maximum current rating for any given port is
not exceeded.
Status LEDs on each port indicate 5VDC and 12VDC operation (OK)
as well as over current limits exceeded (Fault). Additionally, when the
unit has reached 90% capacity of either 5 or 12 Volts a front panel
LED indicates this.
Connections on the Mini Dense Pack
The Mini Dense Pack can service multiple devices on a single port as
long as the total port power rating is not exceeded. Please reference