21
The ENTER key will extinguish the brackets and set the value or the ESC key
will extinguish the brackets and restore the original value. The values set may
not remain in the event of a power cycle unless the settings are made
permanent by selecting ‘Save configuration’ and then press ENTER to confirm
your choice.
In our example setup the IP needs to be set to 192.168.0.78, the subnet and
port default settings already match our requirements.
Fig 5. System menu for our example setup
Next either connect the CC-300 CORIOconsole to the Video Processors using
the serial cable provided or connect the CC-300 CORIOconsole and all Video
Processors to be controlled to your local area network using the IP sockets
with appropriate cables. Consult your network administrator to ensure that
each Video Processor is configured with a different IP address and the
SUBNET matches your network configuration.
Once the settings have been chosen and stored, Press the ESC key to show
the Connection Menu.
Fig 6. Connection Menu showing a duplicate IP has been detected