Tvone CC-300 CORIOconsole Скачать руководство пользователя страница 1

CC-300

CORIOconsole

Operation Manual

Version 1.4

Содержание CC-300 CORIOconsole

Страница 1: ...CC 300 CORIOconsole Operation Manual Version 1 4...

Страница 2: ...CC 300 CORIOconsole Operation Manual Version 1 4 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Страница 3: ...5 3 Initial Operation Check Using Factory Default Settings 19 5 4 Manual configuration of connection 22 5 5 Auto IP Detection 24 5 6 Calypso controller configuration 24 5 7 Locking the keyboard 27 5 8...

Страница 4: ...CC 300 CORIOconsole Operation Manual 2 10 3 Environmental 35...

Страница 5: ...le and exclusive liability to the supplier and manufacturer regardless of the form of action shall not exceed the replacement cost of the materials described herein By using this equipment you have in...

Страница 6: ...uipment for operation that insures FCC compliance Direct all inquiries regarding FCC compliance to TV One Multimedia Solutions 1350 Jamike Drive Erlanger KY 41018 859 282 7303 859 282 8225 Fax Manual...

Страница 7: ...et The AC wall outlet should be installed near to the unit and be easily accessible Do not plug in or attempt to operate an obviously damaged unit 2 2 Water and moisture To reduce the risk of fire and...

Страница 8: ...7 2 5 Intellectual property Some IC chips in this product include confidential and or trade secret property Therefore you may not copy modify adapt translate distribute reverse engineer reverse assemb...

Страница 9: ...mode de veille cette unit est con ue pour consommer une quantit r duite de courant par rapport aux modes normaux d utilisation Lorsque vous n utilisez pas l unit pendant une longue p riode assurez vou...

Страница 10: ...ou des produits nettoyants en a rosol car cela peut endommager l unit Utilisez un chiffon propre et sec 2 4 Emplacement L installation de cette unit doit se faire dans un endroit frais et sec loign d...

Страница 11: ...spera el aparato est dise ado a consumir una cantidad reducida de electricidad en comparaci n con los modos de operaci n normales Aseg rese de desconectar el cable de corriente CA de la toma de la par...

Страница 12: ...ctos de limpieza aerosol ya que podr an da ar el aparato Utiliza un pa o limpio y seco 2 4 Ubicaci n Este aparato se debe instalar en un lugar seco y fresco lejos de fuentes de calor excesivas la vibr...

Страница 13: ...wird als Standbymodus bezeichnet Im Standbymodus verbraucht das Ger t weniger Strom als in den blichen Betriebsarten Wird das Ger t ber einen l ngeren Zeitraum hinweg nicht verwendet ziehen Sie bitte...

Страница 14: ...teln oder Sprayreinigern zu reinigen da dies das Ger t besch digen k nnte Verwenden Sie ein sauberes trockenes Tuch 2 4 Aufstellung Das Ger t sollte an einem k hlen trockenen Ort aufgestellt werden fe...

Страница 15: ...uitstaat staat deze nog in de stand by modus In de stand by modus vergt de eenheid minder stroom dan in de normale aan modus Wanneer u de eenheid voor langere tijd niet gebruikt zorg er dan voor dat...

Страница 16: ...middelen of schoonmaakmiddelen in een spuitbus schoon te maken omdat dit de eenheid kan beschadigen Gebruik een schone droge doek 2 4 Plaatsing Deze eenheid moet ge nstalleerd worden op een koele drog...

Страница 17: ...C2 series units using an IP link At home in both broadcast and display environments the CC 300 CORIOconsole provide access to all controls with a minimum of keystrokes giving fast access to the power...

Страница 18: ...ial so the unit can be returned in the unlikely event that repairs should ever become necessary 4 2 Furnished Accessories Carefully unpack the carton and perform an inventory of the contents In additi...

Страница 19: ...ble with the three types of power cable plugs currently being shipped to make certain you have received the correct power cable If you did not receive the correct cable DO NOT attempt to modify the in...

Страница 20: ...rameters to their original condition select Restore defaults from the system menu then press ENTER to confirm All stored settings are lost when the unit is reset A Firmware update will also perform a...

Страница 21: ...y to display the system menu Fig 4 The System Menu Change the settings to suit your network or serial protocol This is achieved by pressing the soft key next to the item to change Flashing brackets wi...

Страница 22: ...ings already match our requirements Fig 5 System menu for our example setup Next either connect the CC 300 CORIOconsole to the Video Processors using the serial cable provided or connect the CC 300 CO...

Страница 23: ...n window will appear as shown in fig 7 We will set up the configuration for the C2 7100 in our example setup to illustrate the process Fig 7 The connection configuration menu The IP address subnet por...

Страница 24: ...hoice Communication with the configured device can be tested by pressing the soft key for Ping this will attempt to communicate with the configured device four times and the results will be displayed...

Страница 25: ...ll TV One video processors and Calypso controllers with appropriate firmware that are active These are automatically assigned softkey locations and displayed on the connection menu On pressing the AUT...

Страница 26: ...o that trigger event will send a trigger message via the Network to the calypso controller causing the event to take place During this time the status of the communication is displayed on the bottom l...

Страница 27: ...Window Keyer Logo Border Source Trans Macro App F1 F2 F3 F4 System If the key has not already been assigned a message will appear indicating key assignment has been stored and pressing Enter will pla...

Страница 28: ...to Trigger event menu Once a Hot key is set the trigger can be sent while connected to a TVOne video processor by holding the shift key the key set F2 in the above example 5 7 Locking the keyboard To...

Страница 29: ...CC 300 CORIOconsole power were recycled while connected to a video processor it will not be possible to re connect immediately The video processor will not be instantly aware of the lost connection to...

Страница 30: ...onnection configuration menu 6 Incorrect Manufacture The operation of the unit depends on the manufacturer set in the connection configuration menu If a trigger event menu appears when trying to conne...

Страница 31: ...will then show flashing brackets around the adjustable item Adjustments to this item can then be made using the UP and DOWN arrow keys Pressing the soft key adjacent to the menu item the ENTER or ESC...

Страница 32: ...es are properly plugged in and are not damaged and then make certain that all equipment connected to the Processor is working properly Perhaps you have a frozen CC 300 CORIOconsole and you cannot exit...

Страница 33: ...d in warranty for repair without a Return Authorization Number 7 2 TECHNICAL SUPPORT If problems are experienced please read through the symptom topics below in order to resolve the problem After doin...

Страница 34: ...ecific warranties are available upon request to TV One If repairs are necessary under this warranty policy the original purchaser must obtain a Return Authorization Number from TV One and return the p...

Страница 35: ...Tx 1 Rc 2 Tx 2 Rc 3 Rc 3 Tx 6 Rc 6 Tx 9 1 2 Crossover cable RJ 45 PIN RJ 45 PIN 1 Rx 3 Tx 2 Rc 6 Tx 3 Tx 1 Rc 6 Tx 2 Rc 9 2 Power connector PIN Function Center 12V Outside 0V 9 3 RS232 DB9 connector...

Страница 36: ...Options Connector from the Main Unit 10 2 Mechanical Desktop Case HWD 1 75x17x7 9 44x420x200mm With Rack Ears HWD 1 75x19x7 9 44x482x200mm Weight Net 7lb 5oz 3 3kgms 10 3 Environmental Operating Temp...

Страница 37: ......

Отзывы: