Tvone 1T-DA-672 Скачать руководство пользователя страница 10

 

8.0 

REGULATORY COMPLIANCE 

 
The 1T-DA-672 HDMI distribution amp product has been tested for compliance with 
appropriate FCC and CE rules and regulations. The power adaptor/supply has been 
tested for compliance with appropriate UL, CUL, CE, PSE, GS Rules, regulations and/or 
guidelines. This product and power adapter is RoHS compliant. 

 
9.0 

CONTACT INFORMATION 

 
Should you have questions or require assistance with this product in areas not covered 
by this manual, please contact tvONE at the appropriate location shown below. 
 

tvONE USA 

2791 Circleport Drive 
Erlanger, KY 41018  
USA 
Tel  859-282-7303 
Fax 859-282-8225 
[email protected] 
www.tvone.com 
 

tvONE Europe

 

Continental Approach 
Westwood Industrial Estate 
Margate, Kent CT9 4JG, UK 
Tel +44 (0)1843 873311 
Fax +44 (0)1843 873312 
[email protected] 

 

tvONE Latin America 

6991 NW 82 Avenue #8 
Miami, FL 33166 
USA 
Tel  305-396-6275 
Fax 305-418-9306 
[email protected] 
 
 

tvONE Mercosur 

Av Diaz Velez 3965 PB 
Capital Federal (1200) 
Buenos Aires, Argentina 
Tel  +54 11 5917-2525 
Fax +54 11 4032-0281 
[email protected] 

 

tvONE Asia 

16F-4, No.75, Sec. 1 
Xintai 5

th

 Rd, Xizhi Dist 

New Taipei City 22101 
Taiwan R.O.C. 
Tel  +886 2 2698-2296 
Fax +886 2 2698-2297 
[email protected] 

 

tvONE China 

Rm. 1007 Golden Peach Building 
No.1900 Shangcheng Road 
Pudong, Shanghai  
China 200120  
Tel +86 21 5830-2960 
Fax +86 21 5851-7949 
Email: [email protected] 
 
 

 
 
 
 

End of Manual 

Содержание 1T-DA-672

Страница 1: ...1T DA 672 HDMI V1 4 Distribution Amplifier Instruction Manual ...

Страница 2: ... Introduction 2 2 0 Specifications 4 3 0 Checking Package Contents 5 4 0 Connecting the Hardware 5 5 0 Operating The Unit 6 6 0 Troubleshooting 7 7 0 Limited Warranty 8 8 0 Regulatory Compliance 9 9 0 Contact Information 9 ...

Страница 3: ...eld liable for the use of this hardware or any direct or indirect consequential damages arising from its use It is the responsibility of the user of the hardware to check that it is suitable for his her requirements and that it is installed correctly All rights reserved No parts of this manual may be reproduced or transmitted by any form or means electronic or mechanical including photocopying rec...

Страница 4: ...epend largely upon the type and quality of the HDMI display device used For instance some video projectors just look better than others Distance between the DA sources and the display This plays a major role in the final result Long distances are possible but special measures should be taken in order to avoid signal loss These include using high quality cables Line amplifiers or the use of signal ...

Страница 5: ... 45 for 1080p 12 bit DA to Display 15m 45 for 1080p 8 bit 10m 30 for 1080p 12 bit Warranty Limited Warranty 3 Years Parts and Labor Mechanical 1T DA 672 H W D 25 x 102 x 145mm 1 0 x 4 x 5 7 1T DA 672 Weight 0 298g 0 66 lbs Environmental Operating Temperature 0 to 40 C 32 to 104 F Operating Humidity 20 to 90 Non condensing Storage Temperature 0 to 60 C 32 to 140 F Storage Humidity 20 to 90 Non cond...

Страница 6: ...need ever arise to return the unit If you find any items are missing contact your reseller or tvONE immediately Have the Model Number Serial Number and Invoice available for reference when you call 4 0 CONNECTING THE HARDWARE Connect the HDMI Video Source to the input of the 1T DA 672 distribution Amplifier connect its outputs to HDMI compliant devices or monitors and lastly connect the AC to DC P...

Страница 7: ...power LED on the unit will confirm power is present On the rear of the units you ll find a Mini USB port used for factory service Other than connecting cables and applying power there are no other routine operator interventions required SERVICE Port 2 This Mini USB port is reserved for factory service only EDID Operation When first powered on the distribution amplifier will detect and store the ED...

Страница 8: ... 672 HDMI Distribution Amplifier you should attempt to determine what is wrong by attaching each of the source devices one at a time directly to the destination device using the same cables you are using with the expanded system This is a way of determining if the problem is due to bad cables or a problem with the other devices If you are unable to obtain a signal using this simplified path suspec...

Страница 9: ...ective parts replaced become the property of tvONE This warranty does not apply to those products which have been damaged due to accident unauthorized alterations improper repair modifications inadequate maintenance and care or use in any manner for which the product was not originally intended If repairs are necessary under this warranty policy the original purchaser must obtain a Return Authoriz...

Страница 10: ...x 859 282 8225 sales tvone com www tvone com tvONE Europe Continental Approach Westwood Industrial Estate Margate Kent CT9 4JG UK Tel 44 0 1843 873311 Fax 44 0 1843 873312 sales europe tvone com tvONE Latin America 6991 NW 82 Avenue 8 Miami FL 33166 USA Tel 305 396 6275 Fax 305 418 9306 sales latinoamerica tvone com tvONE Mercosur Av Diaz Velez 3965 PB Capital Federal 1200 Buenos Aires Argentina T...

Отзывы: