![TVLogic LVM-070C Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/tvlogic/lvm-070c/lvm-070c_operation-manual_1183365018.webp)
18 Multi Format LCD Monitor
[5] Waveform
•• Range Error
- Used to set whether or not to activate Y MAX,
Y MIN, C MAX, C MIN, Y PICTURE BLINK and C
PICTURE BLINK functions.
- The values of Y MAX, Y MIN, C MAX, C MIN are
indicated in Waveform/Vectorscope.
- If [Y PICTURE BLINK] or [C PICTURE BLINK] is
enabled, the section of image that exceeds the
selected values of Y MAX, Y MIN, C MAX and C
MIN shall blink.
* See section “Other Function -> [8] Range Error”
for more information.
•• Y Max
- Used to set the maximum luma(Y’) level from
0 to 255.
- Pixels with values exceeding the max Y’ level
will blink in the screen, and displayed as red on
the Waveform.
•• Y Min
- Used to set the minimum luma(Y’) level from
0 to 255.
- Pixels with values exceeding the min Y’ level
will blink in the screen, and displayed as red on
the WaveForm.
•• C Max
- Used to set the maximum chroma(C’) level
from 0 to 255.
- Pixels with values exceeding the min C’ level
will blink in the screen, and displayed as red on
the Waveform.
•• C Min
- Used to set the minimum chroma(C’) level from
0 to 255.
- Pixels with values exceeding the min C’ level
will blink in the screen, and displayed as red on
the Waveform.
•• Y Picture Blink
- Used to set whether or not to blink pixels with
values exceeding Y MAX and Y MIN.
•• C Picture Blink
- Used to set whether or not to blink pixels with
values exceeding C MAX and C MIN.