Multi F
orma
t L
CD M
onit
or
23
Menu Contents
[6] SYSTEM
Below is the description for each function of the SYSTEM menu.
1. SET DEFAULT
- Application: For all available inputs.
- Value Range: “NO” , “YES”
- Default Value: “NO”
- Function: Initializes all fixed values back to default setting.
* Exception: Custom 1~3 in Color menu.
Fixed SRC ID String
2. BACK LIGHT
- Application: For all available inputs.
- Value Range: 0 ~ 63
- Default Value: Color calibration value
- Function: Controls the Backlight value of the LCD panel.
3. AUDIO VOLUME
- Application: For all available inputs.
- Value Range: 0 ~ 49
- Default Value: 30
- Function: Controls the volume of the built-in speaker.
4. AUDIO GROUP
- Application: For each input channel.
- Value Range: “GR1” , “GR2” , “GR3” , “GR4”
- Default Value: “GR1”
- Function: Selects the embedded Audio Group of each display input. Selected Audio Group is used
for the Audio Level Meter display and Embedded Audio Group for the audio output.
5. AUDIO OUT SEL
- Application: For all available inputs.
- Value Range: “OFF”, “CH1 G? C12”, “CH1 G? C34”, “CH2 G? C12”, “CH2 G? C34”, “CH3 G? C12”, “CH3 G? C34”,
“CH4 G? C12”, “CH4 G? C34”
- Default Value: “OFF”
- Function: Selects the input source to use with the built-in speaker.
Ch 1~2 and Ch 3~4 of selected display’s embedded audio generates audio L/R through Audio out.
For internal speaker, L/R generates in a single mixed audio.
To select the Embedded Audio group, SYSTEM->AUDIO GROUP.