TVLogic LQM Series Скачать руководство пользователя страница 1

Multi Format 

LCD Monitor

Operation Manual

LQM Series

LQM-171W

multi

Содержание LQM Series

Страница 1: ...Multi Format LCD Monitor Operation Manual LQM Series LQM 171W multi ...

Страница 2: ......

Страница 3: ...residential to correct the interference at his own expense CAUTION Change or modifications not expressly approved by the manufacturer responsible for compliance could void the user s authority to operate the equipment Disposal of Old Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This symbol on the product or on its pa...

Страница 4: ... can cause electric shock and or short internal parts For the same reason do not spill water or liquid on the product Do not attempt to service the product yourself Removing covers can expose you to high voltage and other dangerous conditions Utilize a qualified electronics service specialist for all repairs If any of the following conditions occurs unplug the power cord from the AC outlet and req...

Страница 5: ...th the product When mounting the product on a wall be sure to follow the manufacturer s instruction Use only the mounting hardware recommended by the manufacturer The vents and other openings in the cabinet are designed for ventilation Do not cover or block these vents and openings since insufficient ventilation can cause overheating and or shorten the life of the product Do not place the product ...

Страница 6: ...SD SDI CVBS Auto detecting 1 x SD HD SDI Output Embedded Audio Level Meter Built in audio disembedder and internal speakers Stereo audio out using mini jacks External audio in for line and speaker out Wide Variety of Markers Safety Areas The monitor can be powered by a 12V DC power source Remote control function using RS232 or RS422 User programmable function keys F1 F2 ...

Страница 7: ...ons press the button repeatedly to increase the value of the feature by 1 The value goes back to minimum after reaching the maximum value Rotate the SELECT ENC knob to change the value of selected item The value will automatically will be stored in the memory EEPROM once the OSD disappears LQM 071W Button OSD Controls Indicators and Connections LQM 071W FRONT FACTORY PGM RS 232 ETHERNET USB LEFT S...

Страница 8: ... of the selected input channel VOLUME Used to control the volume SDI OUT Used to select the SDI output source WAVE INTENSITY Used to control the intensity of waveform and vector scope display MENU Used to pop up MENU OSD UP F1 DN F2 Are used to navigate the menu which works same way as the MENU ENC It is also used to activate the user s selected feature when the MENU OSD is not active See chart 4 ...

Страница 9: ... BRIGHT ENCODER Rotate Used to adjust the value of the selected feature and brightness Press Used to control the brightness of selected display 5 CONTRAST ENCODER Rotate Used to adjust the value of the contrast Press Used to control the contrast of selected display 6 CHROMA ENCODER Rotate Used to adjust the value of the saturation Press Used to control the saturation of selected display 7 MENU ENC...

Страница 10: ...itor 10 Controls Indicators and Connections LQM 171W REAR FACTORY PGM RS 232 SDI OUT ETHERNET USB SDI1 CVBS1 INPUT SDI2 CVBS2 INPUT SDI3 CVBS3 INPUT SDI4 CVBS4 INPUT AUDIO OUTPUT REMOTE GPI RS 422 IN OUT DC12V INPUT AC INPUT AUDIO INPUT LQM 171W REAR ...

Страница 11: ...embedded audio in SDI SPEAKER Audio output speaker for audio input or embedded audio in SDI 3 DC IN DC 12V power input 4 REMOTE Provides connection to monitor control equipment via simple GPI contact closure Remote Connector Pin 5 COMMUNICATION RS232 LQM 171 can communicate through RS232 with other equipment It is also used for firmware updates RS422 LQM 171 can communicate through RS422 with othe...

Страница 12: ... Button ROOT Menu POP UP Return to previous Menu Cancel value change Undo MENU ENCODER Navigate the Menu Change the value MENU ENC SW Select the Menu Press and hold for 1 second to activate Menu To confirm and activate the change made in the Menu press the MENU ENC SW If Menu button is pressed after any change was made in the Menu the change will not be stored and will return to the previous value...

Страница 13: ...nge 50 49 Default Value 0 Function Controls the saturation of the selected input display 4 PEAKING Application For each input channel Value Range 0 19 Default Value 0 Function Controls the sharpness of the selected input display 5 ASPECT RATIO Application For each input channel Value Range 4 3 16 9 Default Value 4 3 Function If selected input is in SD input displays in 4 3 or 16 9 aspect ratio 6 I...

Страница 14: ...50 49 Default Value Color calibration Value No default value for custom1 2 3 Function Controls gain value of Green 4 GAIN BLUE Application For all available inputs Value Range 50 49 Default Value Color calibration Value No default value for custom1 2 3 Function Controls gain value of Blue 5 BIAS RED Application For all available inputs Value Range 50 49 Default Value 0 No default value for custom1...

Страница 15: ... CENTER MARKER Application For each input channel Value Range OFF ON Default Value OFF Function Displays the Center Marker for selected channel 4 SAFETY AREA Application For each input channel Value Range OFF 80 88 90 93 98 USER Default Value OFF Function Selects the Safety Area Marker type for selected channel 5 FIT MARKER Application For each input channel Value Range NO YES Default Value NO Fun...

Страница 16: ...ion For all available inputs Value Range 0 99 Default Value 99 Function Controls the position of user defined Vertical Marker lines 9 USER SAFETY AREA H Application For all available inputs Value Range 0 99 Default Value 99 Function Controls the horizontal position of user defined Safety Area 10 USER SAFETY AREA V Application For all available inputs Value Range 0 99 Default Value 99 Function Cont...

Страница 17: ...n for REMOTE PIN3 4 PIN4 Application For all available inputs Value Range See Chart 1 Default Value R TLY C4 Function Selects function for REMOTE PIN4 Menu Contents 4 REMOTE Display Function NONE No REMOTE function assigned R TLY C1 RED TALLY ON for CH1 R TLY C2 RED TALLY ON for CH2 R TLY C3 RED TALLY ON for CH3 R TLY C4 RED TALLY ON for CH4 G TLY C1 GREEN TALLY ON for CH1 G TLY C2 GREEN TALLY ON ...

Страница 18: ...rt 1 Default Value G TLY C4 Function Selects function for REMOTE PIN5 6 PIN6 Application For all available inputs Value Range See Chart 1 Default Value ACT SEL Function Selects function for REMOTE PIN6 7 PIN7 Application For all available inputs Value Range See Chart 1 Default Value PWR STBY Function Selects function for REMOTE PIN7 ...

Страница 19: ...ISPLAY 4P 4P1W1V C H1 C H2 C H3 C H4 C H1 C H2 C H3 C H4 CH1 WAVEFORM CH1 VEC TOR 4P3W 3P1W C H1 C H2 C H3 C H4 CH1 WAVE Y CH1 WAVE Cb CH1 WAVE Cr C H1 C H2 C H3 CH1 WAVEFORM 3P1V 2P1W1V CH1 VECTOR C H1 C H2 C H3 C H1 C H2 CH1 WAVEFORM CH1 VECTOR ...

Страница 20: ... 20 Multi Format LCD Monitor 20 Menu Contents 2P2W 2P2V C H1 C H2 CH1 WAVEFORM CH2 WAVEFORM CH1 VECTOR C H1 C H2 CH2 VECTOR 1P 1P1W C H1 C H1 CH1 WAVEFORM 1P1W1V 1P3W C H1 CH1 WAVEFORM CH1 VEC TOR C H1 CH1 WAVEFORM CH1 VEC TOR ...

Страница 21: ... ID Application For each input channel Value Range OFF MANUAL ANC UMD MAN UMD ANC UMD DYN Default Value OFF Function Activates the ID display for selected display By selecting MANUAL option user can display the edited SRC ID By selecting ANC option monitor extracts the embedded ID string packet from selected SDI input Basic feature of UMD MAN is same as MANUAL mode It also displays SRC ID on the b...

Страница 22: ...L21 708 EMB Default Value OFF Function Selects the Closed Caption for selected display 608 EMB displays embedded 608 closed caption 608 L21 displays SD SDI s 608 Line 21 closed caption 708 EMB displays embedded 708 closed caption Does not support CC708 under OS V2 0 3 CC CH SEL Application For each input channel Value Range CC1 CC2 CC3 CC4 Default Value CC1 Function Selects the channel of closed c...

Страница 23: ...0 Function Controls the volume of the built in speaker 4 AUDIO GROUP Application For each input channel Value Range GR1 GR2 GR3 GR4 Default Value GR1 Function Selects the embedded Audio Group of each display input Selected Audio Group is used for the Audio Level Meter display and Embedded Audio Group for the audio output 5 AUDIO OUT SEL Application For all available inputs Value Range OFF CH1 G C1...

Страница 24: ...ay time period If CONTINUE is selected Menu OSD will stay the on screen until user exits out by pressing the Menu button For ON 30SEC and ON 60SEC Menu OSD will disappear after the selected time period 8 KEY DISPLAY Application For all available inputs Value Range OFF ON Default Value OFF Function Displays the button ID info in the bottom of the screen See Chart 6 The last used button will be high...

Страница 25: ...A Select the SAFETY AREA value LCD BLT SYSTEM BACK LIGHT Control the LCD Backlight ADO GRP SYSTEM AUDIO GROUP Select the Embedded Audio Group ADO OUT SYSTEM AUDIO OUT SEL Select the source for Audio speaker output FUNCTION KEY SELECT LIST 11 SYSTEM VER Application For all available input Value Range N A Default Value N A Function System Version info of the monitor OS Firmware Version MAIN Main FPG...

Страница 26: ...essories RACK MOUNT ANY DISPLAY UP TO 24 Carrying Case _U ˉ ˉ ˉ ZYˉ Wˉ ˉ ˉ Y ˉ X ˉ V Mount X ˉ Tripod Head Hood ND Filter X ˉ Y ˉ External Filter ˉ ˉ Rack Mountable Kit Y ˉ ˉ ˉ X ˉ _U ˉ ˉ ˉ X ˉ X ˉ X ˉ X ˉ X ˉ _U ˉ ˉ ˉ _U ˉ 9 inch 7 inch 8 4 inch 24 inch 17 inch 15 inch ...

Страница 27: ......

Страница 28: ...gu Seoul 153 782 KOREA Tel 82 2 2026 1333 Fax 82 2 2026 1339 Email support tvlogic co kr JHJUBM SPBEDBTUJOH 4ZTUFN BE Developed by FOR MORE INFORMATION PLEASE VISIT http www tvlogic co kr 12F ACE HIGH END TOWER 8 Gasan Dong Geumchoen Gu Seoul Korea 153 802 Tel 82 70 8668 6611 Fax 82 2 2026 1339 Email support tvlogic co kr ...

Отзывы: