PR182335   |   Rev. E   |   Page 5 of 15

3. Run wire through hole in the pole

4. Insert Cable Gland/Grommet into hole in 

the pole 

OR

OR

Содержание Gateway 3.1

Страница 1: ...English Gateway3 1 Installation Manual PR182335 Rev E 03 12 2019 ...

Страница 2: ...PR182335 Rev E Page 2 of 15 TVILIGHT PROJECTS BV Beechavenue 162 180 1119 PS Schiphol Rijk the Netherlands NL 31 0 20 760 7380 info tvilight com www tvilight com ...

Страница 3: ... box M16 Cable Gland Pole ID Label You ll need 5 5m Cable Gateway v3 1 OR 20 mm Rubber Grommet Drill M16 Threaded OR 20 mm Generic Strap x 2 Max 13mm Min 8mm Scan Go App Available in the Apple App Store and in the Google Play Store ...

Страница 4: ...ire through Cable Gland Grommet 2 Drill hole into the pole M16 threaded Cable Gland OR 20 mm Grommet 5m Note For added protection against rust the use of an anti corrosion spray such as WD40 Corrosion inhibitor or equal is recommended OR ...

Страница 5: ...PR182335 Rev E Page 5 of 15 3 Run wire through hole in the pole 4 Insert Cable Gland Grommet into hole in the pole OR OR ...

Страница 6: ...PR182335 Rev E Page 6 of 15 5 Screw Cable Gland OR press Grommet into the pole OR 6 Strap product to the pole THIS SIDE UP Ensure Tensioning Tool is set to maximum tension 4 Tensioning Tool ...

Страница 7: ...ev E Page 7 of 15 7 Apply Pole ID Label to the pole Ensure that the Product and Pole ID Labels match SAME www tvilight com TVI GW 01 0014 www tv iligh t c om TV I G W 01 00 14 www tvilight com TVI GW 01 0014 1 m ...

Страница 8: ...The location of the new device is determined by Scan Go s GPS and it will be indicated on the map 5 The Device Serial Number will be added when scanning the QR Code with the camera 6 Fill in the required fields the ones with an asterisk select the device type and also select the type of ballast PWM or DALI Logarithmic or DALI Linear Note The type of ballast must be known before installation 7 Pres...

Страница 9: ...PR182335 Rev E Page 9 of 15 Wiring Diagram AC in N AC in L Junction Box AC in L AC in N WARNING If not correctly connected product might not function or it might be permanently damaged ...

Страница 10: ...To Mains Naar Mains Armature Armatuur Tvilight Gateway Junction Box Aansluitset L L L L N N N N GND GND GND L N GND AC In L AC In N Brown Blue GND Green Note For added protection an external circuit breaker at the power input of the product is recommended Circuit breakers such as the ELeQ LS 94 5L2408 or similar rated products are acceptable ...

Страница 11: ...plains how to make an Ethernet connection in the Gateway v3 1 Required Parts 1 x Wiska Pressure Compensation Cable Gland ESVG 20 RAL 7035 M20 Manufacturer Part 10060974 1 x Wiska Reduction Sealing Insert RDE 20 M20 Manufacturer Part 10062185 Category 5 6 or 7 Ethernet Cable without Connector 8 mm max Cable diameter 2 x RJ45 Connector for Ethernet Cable Required Tools RJ45 Ethernet Cable Crimping T...

Страница 12: ...ns PR182335 Rev E Page 12 of 15 A2 Insert and tighten the M20 Venting Cable Gland in the open hole A3 Remove Sealing Nut from the M20 Venting Cable Gland and insert the Reduction Sealing Insert Note Installation Torque of Venting Cable Gland 4 Nm ...

Страница 13: ...ndix Ethernet Cable Connection Instructions PR182335 Rev E Page 13 of 15 A4 Put the Sealing Nut back onto the Venting Cable Gland A5 Run the Ethernet Cable without connector through the Venting Cable Gland ...

Страница 14: ...Appendix Ethernet Cable Connection Instructions PR182335 Rev E Page 14 of 15 A7 Place connector onto Ethernet Cable and crimp it into place A6 Strip the Ethernet Cable ...

Страница 15: ...s PR182335 Rev E Page 15 of 15 A9 Tighten the Venting Cable Gland to achieve a watertight seal between the Cable Gland and the Ethernet Cable Note Installation Torque of Cap Nut 3 Nm A8 Connect the Ethernet Cable to the Ethernet port on the GW PCB ...