XIIMUS 4K CL User Manual. Model: 4096CT. Version 1.4
10.2
APPENDIX B: Timing diagrams
10.2.1 B1:
Parallel colour channels output modes
Version: 2.02
Date:
9 June 2006
Firmware L1: R18 for 20 MHz models
R17 for 25 MHz models
R16 for 33 MHz models
R15 for 40 MHz models
Firmware L2: D14
FVAL is constantly HIGH. DVAL is identical to LVAL.
TVI XIIMUS 4096CT
Parallel Output Modes
Symbol
Parameter
Min.
Max.
Unit
T1
NewLine low (CC1)
80
-
ns
T2
Line Scan Period
3 x
4096
pixels 20 MHz
25 MHz
33.3 MHz
40 MHz
210
168
126
105
-
-
-
-
µs
T3
Delay to Change of Line 20 MHz
25 MHz
1
33.3 MHz
40 MHz
0.39
0.45
0.52
0.54
0.44
0.49
0.55
0.565
µs
T4
Effective Integration Time
2
-
µs
T5
Delay to Exposure Control active (CC2 … CC4)
2
-
µs
1
Please note the jitter of one STROBE clock period.
There is no jitter, if the Line Scan Period equals an even number of pixel clocks.
© TVI Vision, 14 July 2006 page 30 ( 56 )