ZS3L Datasheet
Hangzhou Tuya Information Technology Co., Ltd.
10
V1.0.1
3.3 RF Current Consumption
Table 3-3 Current consumption during constant transmission and receiving
Working
Status
Parameter
Average
Value
Maximum
Value
(Typical
Value)
Unit
Mode
Rate
TX Power/
Receiving
TX
250 kbit/s
+20 dBm
200
206
mA
250 kbit/s
+10 dBm
62
64
mA
250 kbit/s
+0 dBm
26
28
mA
RX
250 kbit/s
Constant
receiving
10
12
mA
250 kbit/s
Constant
receiving
10
12
mA
250 kbit/s
Constant
receiving
10
12
mA
3.4 Working Current
Table 3-4 Working current
Working Mode
Working Status (Ta = 25°C)
Average
Value
Maximum
Value (Typical
Value)
Unit
EZ
The module is in EZ mode.
10
40
mA
Connected and
idle
The module is connected to the
network.
4.2
5
mA
Deep sleep
mode
The module is in deep sleep
mode, with 64 KB flash memory.
5
μA