7
SS 465 Chemtraveller
®
SS 435 Chemtraveller
®
Item
Description
1
Short Frame
2
1" Valve/Nozzle
3
1" Poly Short Nipple
4
825 Meter
5
1" Hose Barb
6
Hose Clamp
7
1" x 12' EPDM Discharge Hose
8
1" x 9' EPDM Suction Hose
9
1" Poly Street Elbow
10
1" Ball Valve
11
1" Female Coupler
12
Tall Frame
13
Push Nut
14
Wheel, 6" x 1.5"
15
Spacer
16
Shaft, 1/2" Diameter x 19.5" Long
17
1" Male Adaptor
18
Double Tap Bushing
19
Suction Tube
20
2" Female Coupler
21
2" Male Coupler
22
2" x 1" Reducer Bushing
Bill of Materials
Kit Number
Includes
400KTG8830 2, 3, 4, 5, (2) 6, 7
400KTG9342 17, 11, 10, 18, 9, 445F1863 Suction Tube
400KTG9341 20, 21, 22, 3, 10
400KTF6867 (2) 13, (2) 14, (2) 15, 16
400KTF6853 12, 400F6679 Flange & Hardware
7
6
5
4
3
2
1
8
9
10
11
12
13
14
15
16
Bottom Suction Kit
400KTG9341
Top Suction Kit
400KTG9342
17
22
20
21
18
19
KIT 400KTG9341 Instructions
1.
Use PTFE tape or thread sealant on all
joints.
2.
Thread 2” cam adapter (item 21) into tank
discharge valve and tighten.
3. Assemble remaining fittings as shown.
4.
Close valve on pump outlet hose.
5.
Connect cam Adapter (item 21) on suction
hose to tank.
6.
Open tank valve, then open suction hose
valve.
7. Close tank valve when dispensing is
complete.
KIT 400KTG9342 Instructions
1.
Use PTFE tape or thread sealant on all
joints.
2.
Install suction tube (item 19) and adapter
(item 17) into bushing (item 18) and
tighten.
3. Extend sucion tube (item 19) to required
length, then install bushing (item 18) on
drum.
4.
Install other components as shown.
5. Engage coupler adapter and open ball
valve.
6.
Close ball valve and disconnect coupler to
remove. Allow fluid to drain into tank.