Tuthill FILL-RITE FR1200 Скачать руководство пользователя страница 3

fillrite.com  |  tuthill.com

3

     |    H-SERIES FUEL TRANSFER PUMPS

INSTALLATION AND OPERATION MANUAL

Before You Begin 

About This Manual 

From initial concept and design through final production, your Fill-Rite fuel transfer pump is built to provide years of trouble-free use. To ensure the safety 
of yourself and those around you, it is critical that this manual is read in its entirety prior to attempting to install or operate your new purchase. We strongly 
urge that any installer and operator become familiar with the terms, diagrams, and technical data in this manual and pay close attention to warning 
symbols and definitions. At Tuthill, your satisfaction with our products is paramount. If you have questions or need assistance with your product, please 
contact Customer Service at 1-800-634-2695 (M-F, 8am-6pm EST/EDT).

• 

Adjustable Electrical Junction Box 

Rotates 180 degrees to provide ease of electrical wiring installation 
in tight quarters no matter the inlet bung location 

• 

Reliable, Heavy-Duty Power Switch Lever 

Features a cast metal stop that withstands heavy use in the 
most rugged environments

• 

Locking Bar Defense 

Elongated bar simplifies the pad locking process to prevent theft

• 

Focused Component Weight Reduction 

Preserves expected heavy-duty performance while 
improving installation ease

• 

Premium Paint Shield 

An exemplary corrosion resistant barrier for long field life

• 

Thermally Protected Motor 

Prevents overheating to ensure maximum motor life 

• 

Telescoping Inlet Metal Suction Pipe* 

Adjustable from 20 to 34 inches in length, allowing for universal 
installation on a multitude of tank sizes and shapes

*

Not included with SD models

• 

Intake Strainer Safeguard 

Protects the pump by blocking particles created by contamination

• 

Certifications 

– UL, cUL

Symbols and Definitions 

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in moderate or minor injury. 

Indicates information considered important but not directly hazard related.

Fueling Requirements

The Fill-Rite FR1200, FR2400, FR4200, FR4400, FR600 as well as SD1200 and SD600 models are designed and approved for use with the following 
flammable and combustible fluids: gasoline and gasoline blends up to 15% or E15, diesel, biodiesel blends up to 20% or B20, kerosene, and mineral spirits. 
Please take all necessary precautions when handling flammable liquids.

Power Source Requirements

Depending on the Fill-Rite model, supply line power will either be 12V DC, 24V DC, or 115V AC. The pump motor nameplate located next to the switch lever will 
provide detailed electrical information. Please refer to the appropriate electrical instructions found starting on 

Page 7

 (DC power) or 

Page 10

 (AC power).

Items that may be needed for installation:

Steel pipe wrench 14-24", open end wrench or socket (7/16", 11mm), T-25 Torx driver, utility knife, angle grinder or hacksaw (optional), wire cutters, wire 
stripper/crimper, and thread sealant (optional).

Note: Tuthill provides Teflon

®

 tape for all models as listed on 

Page 16

.

H-Series Fuel Transfer Pumps Have the Following Features 

Содержание FILL-RITE FR1200

Страница 1: ...MADE IN USA H SERIES FUEL TRANSFER PUMPS FR1200 FR2400 FR4200 FR4400 FR600 SD1200 SD600 Installation and Operation Manual ...

Страница 2: ...umber and purchase date of your fuel transfer pump Protect yourself as well as those around you by observing all safety instructions and adhering to all danger warning and caution symbols Please register your Fill Rite product via info tuthill com product_registration IMPORTANT RETURN POLICY Please do not return this product to the store For all warranty and product questions please contact Tuthil...

Страница 3: ... from 20 to 34 inches in length allowing for universal installation on a multitude of tank sizes and shapes Not included with SD models Intake Strainer Safeguard Protects the pump by blocking particles created by contamination Certifications UL cUL Symbols and Definitions Indicates a hazardous situation which if not avoided will result in death or serious injury Indicates a hazardous situation whi...

Страница 4: ...static wire conductive hose when pumping flammable liquid Improper mechanical installation or use can result in serious injury or death Never smoke around or near a fuel tank or transfer pump Open flames or a spark when pumping a flammable liquid will result in a fire Improper electrical wiring or installation will result in serious injury or death Threaded pipe joints and connections must be seal...

Страница 5: ...an integral bypass valve to recirculate the fluid when the pump is operating with the nozzle closed Diagram 2 1 2 Min 1 2 Min Stationary Tank For stationary fuel tanks the pump mounts to the tank bung by way of the pump inlet flange Given the different sizes of stationary fuel tanks a custom suction or inlet pipe may be necessary We recommend 1 NPT black iron pipe that is extended to a length of a...

Страница 6: ...5 screws and locate wires DC Voltage 2 wires Black and Red AC Voltage 3 wires Black White and Green which is attached to internal ground screw Ensure that gasket remains in place upon re attachment of junction box Step 6 Feed wires from power source through NPT opening into junction box For DC models use the black cable connector For AC models attach conduit directly to NPT opening Step 7 Nozzle b...

Страница 7: ...ed for 24V DC Regardless of how supply line power is provided i e via a battery or hard line Tuthill requires the circuit contain a fuse to prevent against electrical shorts For 12V DC a 30 amp fuse is necessary while for the 24V DC circuit a 20 amp fuse Voltage drop in wiring varies depending on the distance from the battery to the pump and the gauge of the wire used If the distance is greater th...

Страница 8: ...between the frame and the junction box see Step 6 diagram on Page 6 12 AWG cable not supplied with pump only models ATTACH GROUND WIRE TO VEHICLE BODY NPT CONDUIT HOLE THREADED 2 T 25 TORX SCREWS EXTERNAL GREEN GROUND SCREW JUNCTION BOX GASKET JUNCTION BOX CAP CAN BE ROTATED 180 EARTH GROUND SYMBOL Diagram 3 Diagram 4 Mobile Tank Wiring to a Vehicle Electrical System 1 Before electrical installati...

Страница 9: ...f the wiring from the power source to the pump is greater than 18 refer to the applicable Electrical Code national international or local to ensure the wire is of the correct size for the application Negative Ground System Common This electrical system is common within most vehicles utilizing a 12V DC power source In this instance the positive battery terminal supplies power to all devices such as...

Страница 10: ...dous locations Class I Division 1 It is highly recommended that any repairs be done by an authorized distributor to avoid voiding the warranty It is very important to maintain the explosion proof integrity of the motor and system components Electrical wiring should be performed ONLY by a licensed electrician in compliance with local state and national electrical codes NEC ANSI NFPA 70 NFPA30 and N...

Страница 11: ...Be certain to properly insulate the connections with the appropriate wire nuts or other connectors Note the ground wire MUST be connected Ground wire connection is inside the junction box Diagram 6b 4 Fold the wires back into the junction box and replace the cover making sure the cover gasket is in place 115V AC Pump Junction Box FR SD600 Series AC Fuel Transfer Pumps 115V AC Wiring Diagram for FR...

Страница 12: ...h or serious injury Troubleshooting The following troubleshooting guide is provided to offer basic diagnostic assistance in the event you encounter abnormal service from your Fill Rite fuel transfer pump If you have questions please feel free to contact Tuthill Customer Service at 1 800 634 2695 M F 8am 6pm EST EDT or by email at fillritesales tuthill com Please disconnect all power supply sources...

Страница 13: ... Tuthill Customer Service at 1 800 634 2695 M F 8am 6pm EST EDT Motor stalls fuse blows thermal protector trips repeatedly Bypass valve sticking Remove and inspect valve must move freely and be free of debris Low voltage Check incoming supply line voltage Excessive rotor or vane wear Check rotor and vanes for excessive wear or damage Debris in pump cavity Clean debris from pump cavity Motor overhe...

Страница 14: ...0 13 20 15 13 Bypass Pressure 16 PSI Minimum Dry Vac 5 IN HG At Sea Level 70 F 21 1 C Suction Lift 8 Maximum Outlet Head 37 Maximum Inlet 1 NPT Outlet 3 4 NPT 1 NPT 3 4 NPT 1 NPT 3 4 NPT Mount 2 NPT Inlet Bung Warranty Limited Lifetime Warranty 1 Year Limited Lifetime Warranty 1 Year Product Parts Product Materials Pump Housing Cast Iron Rotor Powdered Iron Vane Sintered Bronze Strainer Mesh Stain...

Страница 15: ... H SERIES FUEL TRANSFER PUMPS INSTALLATION AND OPERATION MANUAL FR4200 Dimensions displayed in inches 3 4 4 3 2 5 8 4 13 0 11 1 4 2 8 4 2 5 4 3 11 8 13 7 FR1200 FR2400 FR4400 FR600 SD1200 and SD600 Dimensions displayed in inches ...

Страница 16: ...07CL FR4204H Pump Only Model 12V DC 1 FR4210H Manual 12 Metal Telescoping 20 34 12 AWG at 18 FR4210HARC Auto Arctic 20 Swivel FR4210HB Ultra Hi Flow 12 FR4210HD Auto Diesel 12 FR4210HDS Auto Diesel 12 Swivel FR4210HBFQ Ultra Hi Flow 18 10 AWG at 25 with clamps Filter FR4210HN 12 AWG at 18 FR4211H Manual 12 901C FR4211HL Manual 12 901CL FR4211HLN 901CL FR4211HN 901C FR4219H Manual 12 TT10AN FR4406H...

Страница 17: ...fillrite com tuthill com 17 H SERIES FUEL TRANSFER PUMPS INSTALLATION AND OPERATION MANUAL 1200 Series Performance Curve 2400 Series Performance Curve ...

Страница 18: ...fillrite com tuthill com 18 H SERIES FUEL TRANSFER PUMPS INSTALLATION AND OPERATION MANUAL 4200 Series Performance Curve 4400 Series Performance Curve ...

Страница 19: ...m 19 H SERIES FUEL TRANSFER PUMPS INSTALLATION AND OPERATION MANUAL 600 Series Performance Curve METER STRAIGHT PIPE FILTER HEAD STREET ELBOW NOZZLE FILTER HOSE STRAIGHT PIPE SWIVEL Proper Accessory Configuration Accessories ...

Страница 20: ...erosene and Petroleum Oils compatible 12 FRH07512 FRH10012 14 FRH07514 FRH10014 20 FRH07520 FRH10020 Meter Mechanical 800 807CMK Gallons 807CLMK Liters 900 901CMK4200 Gallons 901CLMK4200 Liters Digital 900 900CD Programmable 900CDP Programmable with Integral Pulsar TT TT10AB BSPP Aluminum TT10ABC BSPP Nickel Plated TT10AN NPT Aluminum TT10ANC NPT Nickel Plated Swivel Multi Plane S075H1314 S100H131...

Страница 21: ...ction Cover Kit Junction cover seal fasteners 4 KIT120SL Seal Kit O ring shaft seals retainer clip 5 KIT120BV Bypass Service Kit Bypass valve valve spring bypass cap O ring seal 6 KIT120NB Nozzle Boot Kit Nozzle boot attaching hardware 7 KIT120BG Inlet Flange Kit Inlet flange bung attaching hardware inlet seal screen 8 KIT120SG Inlet Gasket and Screen Gasket for inlet bung and screen 9 KIT120SWH S...

Страница 22: ...ins affixed to the pump at all times Safety Testing Approvals The Fill Rite line of pumps have been safety tested for regulatory compliance This product family is approved by Underwriters Laboratories UL Tuthill Corporation 8825 Aviation Drive Fort Wayne Indiana 46809 USA P 800 634 2695 01 260 747 7524 F 800 866 4681 tuthill com fillrite com sotera com ...

Отзывы: