The SKORPION™ Process Air Heater from 

Tutco  SureHeat

 represents the perfect 

combination of power, size, reliability and control in Air Heating technology.   

The SKORPION™ Process Air Heater produces air temperatures from 1200°F (650°C) (120V 
version) to 1400°F (760°C) (230V version).  A closed-loop PID temperature control system 
ensures precise control of your process.  

If used correctly, an element life of 5000 hours or greater can be expected. 

Limited Warranty 

Tutco  SureHeat

  Products  Inc.  (“OSPI”)  warrants  that  this  Product  will  be  free  of  defects  in  material  and 

workmanship  for  a  period  of  two  (2)  years  from  date  of  purchase.    Buyer’s  sole  remedy,  and 

Tutco 

SureHeat 

obligation, under this warranty is limited to (at 

Tutco  SureHeat

 option) repairing or replacing 

any  non-conforming  Product  or  granting  a  credit  to  Buyer  for  the  Product.  A  replacement  Product 
assumes the remaining warranty of the original Product.  This warranty shall not apply to any Product 
that has been repaired or altered, except by 

Tutco  SureHeat

, or that has been subjected to abuse or 

mishandling.   

Tutco  SureHeat

  express  warranty  applies  only  when  the  Product  is  properly  operated  in 

accordance with specifications and instructions.  

THE  FOREGOING  CONSTITUTES  THE  SOLE  AND  EXCLUSIVE  REMEDY  OF  BUYER.  
OSPI DISCLAIMS ALL OTHER REPRESENTATIONS AND WARRANTIES, EXPRESS OR IMPLIED, 
WITH 

RESPECT 

TO 

THE 

PRODUCT, 

INCLUDING 

THE 

IMPLIED 

WARRANTIES 

OF 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  IN NO EVENT SHALL OSPI BE 
LIABLE  FOR  ANY  SPECIAL,  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES,  INCLUDING  LOST 
PROFITS OR REVENUES OR ANY OTHER COSTS OR DAMAGES. SOME STATES DO NOT ALLOW 
LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS AND/OR DO NOT ALLOW THE 
EXCLUSION  OF  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES,  SO  THE  ABOVE  LIMITATIONS 
AND EXCLUSIONS MAY NOT APPLY.   

To obtain service under this warranty, contact the 

place of purchase

 within two (2) years following date of 

purchase.  The following information must be provided in writing: 

(i)

Order number under which the Product was shipped;

(ii)

Model/Serial 

Number; 

and

(iii)

Reason 

for 

rejection.

Failure to follow this procedure shall void the warranty. 

Tutco SureHeat

 reserves the right (i) to examine the failed Product to determine the cause of failure and 

patterns of usage and (ii) to be the sole judge as to whether the Product is defective and covered under this 
warranty. 

The  information  contained  in  this  manual  is  based  on  data  considered  to  be  true  and  accurate.  
Reasonable precautions for accuracy has been taken in the preparation of this manual, however 

Tutco 

SureHeat

  assumes no responsibility for any omissions or errors, nor assumes any liability for damages that 

may result from the use of the product in accordance with the information contained in this manual. 

Tutco SureHeat

  

1

29 

Portsmouth Avenue  

Exeter, NH  03833   USA  
800-258-8290 

[email protected]

www.tutcosureheat.com

1

Содержание SKORPION F075615

Страница 1: ...rical codes and use proper wiring BURN HAZARD Avoid contact with the heater nozzle during or soon after operation EXPLOSION HAZARD Heater produces extremely high temperatures Do not use in hazardous environments and or near explosive or reactive gases or combustible materials O OP PER ERAT ATIN ING G INSTRUCTIONS 2 6 2018 SKORPION Process Air Heater ...

Страница 2: ...D WITH RESPECT TO THE PRODUCT INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL OSPI BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING LOST PROFITS OR REVENUES OR ANY OTHER COSTS OR DAMAGES SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS AND OR DO NOT ALLOW THE EXCLUSION OF INCIDENTAL OR CONSE...

Страница 3: ... F205513 N A F205494 F075616 3 0kW 230V 1 Ø 13A F205502 F205499 F205486 F205512 N A F205494 F076008 4 5kW 230V 1 Ø 20A F205614 F205499 F205486 F205604 N A F205494 Complete Unit without Blower F075869 1 5kW 120V 1 Ø 12 5A F205526 F205499 F205486 N A F205549 F205494 F075835 3 0kW 230V 1 Ø 13A F205526 F205499 F205486 N A F205549 F205494 F076029 4 5kW 230V 1 Ø 20A F205614 F205499 F205486 N A F205549 F...

Страница 4: ...d screw terminal Additional protective earthing can be attached to the aluminum base plate if desired Basic Operation 1 Turn SKORPION air heater ON using two switches 1 1 Switch S1 blower sends power to the blower and to heater switch S2 1 2 Switch S2 heater sends power to the heater control circuit 1 3 Note for heater safety S2 heater cannot turn ON without S1 blower ON 2 Adjust airflow via a rot...

Страница 5: ...overheats bright orange color the photo detector resistance decreases which reduces the control signal which in turn limits power to the heater o If the air temperature in the housing reaches an unsafe level the thermistor resistance decreases which reduces the control signal which in turn limits power to the heater o A small fixed resistor in series with the control signal sets element and air te...

Страница 6: ...750 C 1400 F 12 SCFM 340 SLPM 12 SCFM 340 SLPM 22 SCFM 623 SLPM see note FOR SKORPION models without Blower external air source A The maximum temperature capability of heater will depend entirely on the airflow rate produced by external air source Higher airflow rates than those produced by the standard SKORPION blower will yield lower maximum temperatures B External air supply must be turned ON p...

Страница 7: ...ich attach the aluminum base plate to the main heater plastic structure 4 With the top cover plate and the aluminum plate removed you now have access to the top and bottom mounting tabs on the temperature controller 5 While lifting the top and bottom white plastic mounting tabs gently push the temperature controller halfway out of the faceplate 6 Using masking tape or other method mark each wire g...

Страница 8: ...d apply new heat sink putty on the back of the new SSR 6 Mount SSR onto aluminum base plate with the mounting screws and reconnect wires 7 Replace the black plastic top cover plate and reattach mounting screws IV Replacing the Blower 1 Turn heater blower switches OFF and disconnect from power source 2 Use a flat screwdriver to remove pry open the wiring cover under the stainless nozzle tube 3 Remo...

Страница 9: ...SKORPION 1 5kW 3 0kW 8 ...

Страница 10: ...SKORPION 4 5kW 9 ...

Страница 11: ...SKORPION Without Blower 1 5kW 3 0kW 4 5kW 10 ...

Страница 12: ...Tutco SureHeat 129 Portsmouth Avenue Exeter NH 03833 USA Tel 800 258 8290 support sureheat com www tutcosureheat com ...

Отзывы: