4
HEATER MODELS AND PARTS LIST
Serpentine II Elements
(used with Housing/Exchanger Part #F029763)
* Temperatures are measured by 3/16” “K” T/C sensor Part #F039272 mounted inside TC holder #F029485 TC Holder mounted on exit of #F029763 Housing Assembly
• Use of other sensor types and/or locations can result in heater damage if used for process control.
• Minimum airflow for accurate control is 60 SCFH (28 SLPM)
• Maximum air temperature is as listed in table above - Operating above this will void warranty
Serpentine VI Elements
(used with Housing/Exchanger Part #F057088)
* Temperatures are measured by 3/16” “K” T/C sensor Part #F039272 mounted inside TC holder #F040299 TC Holder mounted on exit of #F057088 Housing Assembly
• Use of other sensor types and/or locations can result in heater damage if used for process control.
• Minimum airflow for accurate control is 120 SCFH (57 SLPM)
• Maximum air temperature is as listed in table above - Operating above this will void warranty
Part
Number
F029765
F029766
F029767
F060418
Maximum
Watts
2000
2800
3600
3600
(2-Stage)
Maximum
Volts
240
240
240
240
Maximum
Amps
8.3
11.7
15.0
15.0
Maximum
Pressure (PSI)
25
25
25
25
Maximum
Temperature*
1400ºF / 760ºC
1400ºF / 760ºC
1400ºF / 760ºC
1500ºF / 815ºC
Part
Number
F040291
F040292
F061429
F056548
Maximum
Watts
5000
6000
6000
(2-Stage)
8000
Maximum
Volts
240
240
240
240
Maximum
Amps
20.8
25.0
25.0
33.3
Maximum
Pressure (PSI)
25
25
25
25
Maximum
Temperature*
1300ºF / 705ºC
1400ºF / 760ºC
1500ºF / 815ºC
1400ºF / 760ºC
Содержание Serpentine II
Страница 1: ...O P E R A T I N G M A N U A L Serpentine II and Serpentine VI Air Heaters ...
Страница 8: ...TYPICAL WIRING AC AC L1 L2 L1 H1 TC TC Output Temp Control Power Control Heater H1 H2 G 8 ...
Страница 11: ...11 9 ...
Страница 12: ...10 12 ...
Страница 13: ...SERPENTINE VI ELEMENTS 13 ...
Страница 14: ...14 ...