Initial Configuration
TUT Systems, Inc
Page 19 of 104
P/N
220-06288-20
Chapter 3 - Initial Configuration
You may configure the SMS2000 via a serial interface or a Telnet connection as
described in the following sections.
Establishing a Connection with the
SMS2000
Establishing a Connection Via a Serial
Interface
Note:
Verify you have installed the SMS2000 on a rack or shelf with air
circulating above and below the SMS2000.
Perform the following steps to configure the SMS2000 via a serial interface connection:
1. If you have not already done so, connect a PC to the DB-9 RS-232 console port
connector on the SMS2000 using the DB-9 RS-232 null modem cable supplied.
2. Using Microsoft Windows 95 or later, from the Windows task bar, click
Start
.
3. From
the
Start
menu, select
Programs
.
4. From
the
Programs
menu, select the
Accessories/Communication
menu and then
select the
HyperTerminal
folder.
5. Click
the
HyperTerminal
icon.
The
Connection Description
dialog box displays.
6. Enter a name (for example, SMS2000) and select an icon for the connection, then
click
OK
.
The
Connect To
dialog box displays.
7. Select
Connect Using Direct to COM 1 or 2
(the COM port on this PC).
8. Click
OK
.
9. Click
Configure
.
10. Set the following parameters in the
Connection
tab:
•
Set
Bits per second
to
9600
.
•
Set
Data bits
to
8
.
•
Set
Parity
to
None
.
•
Set
Stop bits
to
1
.
•
Set
Flow control
to
None
.