33
Decompression stop violation lock and Out of Measurement
range lock
In this mode the computer is locked until 48 hours have elapsed.
The IQ-800 won't move to dive plan or dive set mode.
•
Α: Use this button to switch modes
•
C: This button works normally in selected mode
•
Β: This button works normally in selected mode
•
Ε: Water detection button: no function.
Out of Measurement range warning:
If the computer enters this
warning mode, all of the display segments will blink as shown below.
The sound or vibrating alarm will operate twice for three seconds.
The warning is recorded in the log. (Fig. 33)
WARNING
An IQ-800 displaying an “Out of Range” warning is incapable of
displaying other critical information such as depth, time, ascent rate,
PO
2
, OLI, and deco stop violations, and required decompression
stops. You should not under any circumstances use an IQ-800
in such a way that would cause the Out of Range Warning to be
displayed.
Under such conditions, the risk of serious personal
injury or death would be substantial.
Figure 33