3
Debugging Functions
Operating instruction
1.
After powered on, the LCD screen on the control board will display the default state showing the
current working mode.
2.
There are 4 buttons on the control board: UP, DOWN, ENT, and ESC, as shown in Figure 3-1.
UP:
to move upwards or increase the value.
DOWN:
to move downwards or decrease the value.
ENT:
to enter a menu setting item or confirm the current modified value.
ESC:
to return to the previous menu or cancel the current operation.
Menus
1. Position adjustment of the swing barrier
Type: zero (default)
Left limit
Right limit
2. Passing mode
Opening mode: Two-way swipe (default)
Left free, Right swipe
Left swipe, Right free
Two-way free
Left prohibit, Right swipe
Left swipe, Right prohibit
Left prohibit, Right free
Left free, Right prohibit
Two-way prohibit
3. Opening duration (Press ‘ENT’ to modify)
After the gate is opened, it will automatically close if no one passes through within a certain time
duration. The default value is 5 seconds. The value ranges from 2 to 60.
www.TURNSTILES.us | [email protected] | 303-670-1099