8
EN
CONTROL
MODULE
LICENSE MENU
If the submitted pin is correct, after choosing OK option the license settings menu will be
displayed. Choose the Back option to return to the settings menu.
In the license settings menu you can define a limit of cycles. When the limit of cycles is
reached, the device will not react to external signals and test mode, and the relevant infor-
mation will be displayed on the screen. Possible values to choose from:
•
None - no limit
•
1k, 10k, 50k 100k and 200k - limit in thousands
TEST MODE
In the test mode the device is working independently.
It performs 5 cycles alternately in both directions. During the test, all the mechanisms
connected to the controller are being used. Work parameters are shown on the screen.
To cancel the test mode choose Back option.
In devices of the BA3, BR2 and GA series the mode is used only in devices equipped in
the rotor’s movement support system.
Caution: While starting the test mode no person can be found within the device moving elements range.
SG SERIES DEVICES
DESCRIPTION OF THE CONTROL MODULE TERMINALS
Symbol
Function in the master driver
Function in the slave driver
IN1
input of the optical sensor 1
input of the settable signal in the left direction
IN2
mass - not used
mass of the input signal
IN3
input of the optical sensor 2
input of the settable signal in the right direction
IN4
mass - not used
mass of the input signal
IN5
input of the optical sensor 3
input of the trigger signal in the left direction
IN6
mass - not used
mass of the input signal
IN7
input of the optical sensor 4
input of the trigger signal in the right direction
IN8
mass - not used
mass of the input signal
IN9
input of the optical sensor 5
input of the fire-fighting signal (normally short circuited)