16 ·
NIMH/NICD BATTERY PROGRAM
These programs are for charging or discharging NiMH (Nickel-Metal-Hydride) or NiCd
(Nickel-Cadmium) battery commonly used for R/C model aplications. To alter the value at
the display, press Start/Enter key to make it blink then change the value using INC or
DEC key. The value will be stored by pressing Start/Enter key once.
To start the process, press Start/ Enter button for more than 3 seconds.
Charging of NiCd/NiMH battery
Discharging of NiCd/NiMH battery
The charger will charge NiCd and NiMh batteries using the charge current set by the user.
NiMH CHARGE
CURRENT 2.0A
NiMH DISCHARGE
0.1A CUT:1.0V
Battery
type
DEC
-
INC
+
Battery
type
DEC
-
INC
+
Batt type
Stop
Elapsed
time
Start
Enter
Charged
capacity
Battery
type
Charge
current
Battery
voltage
'> 3 seconds '
Discharge
current
Battery
type
Battery
voltage
Elapsed
time
Discharged
capacity
Batt type
Stop
Start
Enter
'> 3 seconds
'
NiMH 0.1A 7.42V
DSC 022:45 00890
The screen displays the current state of charging.
To stop the process, press Batt type/Stop key once.
The audible sound indicates you the end of process.
This program is for charging of NiCd/NiMH batteries associated
with R/C models applications. You can press Start/Enter key to
make it blink and then Inc or Dec to change the parameter value.
Press START/ENTER key to store the value.
Set discharge current on the left and final voltage on the right. The
discharge current ranges from 0.1 to 8.0A and the final voltage
ranges from 0.1 to 32.0V). To start the process, press Start /Enter
key more than 3 seconds.
The screen indicates the discharging state. You can press
Start/Enter key to alter discharge current. Press Start/Enter again
to store the value. Press Batt Type/Stop key to stop discharging.
The emitted sound alerts the end of discharging.
Charging NiCd/NiMH battery in the AUTO charge mode
In this program the charger detects the condition of the battery which is connected to the
output and automatically charges the battery. In this mode, you should set up the upper
limit of the charge current to avoid damage by excessive feeding current. Some batteries
of low resistance and capacity can lead to higher current in the auto charging mode.
This program is for charging of NiCd/NiMH batteries. You can
press the Start/Enter button to make it blink and then press the
Dec/Inc button to change the parameter value. Press the
Start/Enter button more than 3 seconds to start the charging
process.
N i M H A u t o C H A R G E
C U R R E N T 2 . 0 A
N i M H 2 . 0 A 9 . 5 2 V
A U T 0 0 0 : 1 3 0 0 0 0 0
ENTER
/
START
Turnigy Mega 1000W