background image

Hextronik AIRplane [6-12]ESC Manual [ Model 2 ]                            Page 3                          7/21/2014 

       

x 3 

Lipo 14S 

       

x 3 

 

 

 

3. Rotation Reverse 

This function is to change the motor rotation direction.   
(for example: Right to Left, or vice versa) 
 

Reverse motor rotation 

     

     

 

 

4. Acceleration   

When gearbox drive system is used. It’s highly recommended to enable the Soft start. 

Because it’s protecting the gearbox not to damage especially large diameter of propeller is used. 
Disable the soft start function when direct drive system is used or being in speed competition   
 

Low: 

 

       

       

 

 

High: 

       

       

   

 

5. Under Voltage 

If the motor battery pack drops to the programmed cut-off voltage, the controller will either ignore, reduce 
the motor speed or stop the motor to ensure that there is enough power for the receiver and servos. Either 
one is active, you can resume to normal operation by pull down the throttle stick and push up again, 

but 

remember that it’s time to land you model! 
Ignore

 

 

 

 

 

 

(motor won’t stop until battery total gone) 

     

     

     

 

Reduce power: 

(reduce motor speed) 

       

       

 

Stop: 

(stop motor) 

       

       

 

 

 6. Timing 

The controller has three timing modes; Automatic works perfect for 

ALL

 types of brushless motor. But for some 

brands or homemade brushless motors, you have to set the right timing for optimal efficiency and power; 7 degree for 
multi-pole motors, 30 degree for out runner motors.   

 

Automatic:   