Operating the Sprayer
·
&
IMPORTANT
The spray system is not for use with wettable powders or water
dispersible
granules. All materials must be in liquid form and premixed prior
to adding them to the tank.
TR460-12/21
16
1) Make sure the machine is on level ground and apply the parking brake.
2) Open the tank cap on the spray tank and fill the tank with the pre-mixed liquid.
NOTE:
Make sure the tank is at least half full before priming the spray system.
3) Set spray lever open for wand.
4) Turn the spray pump on.
5) Bleed the line by spraying the wand back into the tank in 3-4 short bursts.
6) Adjust regulator between 28 and 32 PSI, tighten the lock ring and turn off pump.
7) If pump still won’t pressurize...
8) remove cap on regulator, depress spring retainer 4-5 times until pressure resumes.
9) check supply lines to pump are securely sealed and there are no leaks.
10) also check that the O-Rings are properly seated in the filter housings. Once pressure resumes...
11) Go to the work area.
12) Ensure the area to be maintained is clear.
13) Select the appropriate spray pattern: wide, trim or wand.
a) To spray using the front sprayer nozzles:
i) Move the Wide Spray Lever forward.
ii) Press the spray button on the left handlebar to apply the solution to the work area.
b) To use the spray wand:
i) Remove the wand from the holder.
ii) Move the Wand Spray Lever forward.
iii) Hold the spray wand and point it in the direction to be sprayed.
iv) Squeeze the spray wand trigger to begin spraying.
Cleaning the Sprayer-Daily/Long Term
Always empty and properly clean the sprayer unit immediately after each use and prior to storage.
1) Spray all contents onto a turf area until the spray system is empty.
2) Fill the tank with fresh water.
3) Spray all contents onto a turf area again through the wide nozzle, narrow nozzle and spray wand until
fresh water flows through each. Repeat this cleaning process three times to ensure complete rinsing of the
spray system.
4) Remove, clean, and inspect the three nozzle screens located in the spray nozzle bodies and the main
spray system filter. Replace if necessary. When cleaning the screen be sure the screen housing GASKET
remains in place. The spray system will not build pressure without the gasket.
5) For long-term storage in freezing conditions add an RV type of anti-freeze and cycle it completely through
the spray system.
Refer to the Honda Owner's Manual, included separately with your machine, for more information about
proper long-term storage of the engine. MAINTENANCE AND STORAGE - DAILY
TR460-12/21
Page 16
Содержание TR360
Страница 19: ...Example Service Path TR460 12 21 19 Example Service Path TR460 12 21 Page 19 ...
Страница 24: ...Maintenance Chart Page 24 ...
Страница 26: ...Spraying Systems Nozzle Selection Rates Page 26 ...
Страница 38: ...TR460 12 21 Page 38 TR460 HYDRAULIC SYSTEM Main Drive Circuit TR460 12 21 38 ...
Страница 43: ...TR460 12 21 Page 43 TR360 AND TR460 NOSE CONE TR460 12 21 43 ...