Lit. No. 72393, Rev. 00
10
March 15, 2019
AFTER SPRAYING CLEAN-OUT / MAINTENANCE / STORAGE
AFTER SPRAYING CLEAN-OUT
Read and follow each chemical label's instructions
and warnings.
Wear protective clothing, eye protection, and chemical-
resistant gloves when filling, using, and cleaning sprayer.
Wear additional protective gear, such as face mask or
apron, as recommended on the chemical label.
After every use, fill the sprayer part way with water.
Start the sprayer and allow clear water to be pumped
through the plumbing system and out through the
spray wand.
Refill the tank about half full with plain water and
use a chemical neutralizer such as Nutra-Sol
®
tank
cleaning solution or equivalent, and repeat cleaning
instructions. Flush the entire sprayer with the
neutralizing agent. Follow the chemical manufacturer’s
disposal instructions of all wash or rinsing water.
WARNING
Some chemicals will damage the pump valves
if allowed to soak untreated for a long period
of time. Always flush the pump with water
after use. Do not allow chemicals to sit in
pump for extended times of idleness. Follow
chemical manufacturer's instructions on
disposal of all waste water from the sprayer.
Nutra-Sol
®
is a registered trademark of BASF.
CAUTION
Always use appropriate personal protective
equipment, including gloves and safety
goggles, when filling or emptying sprayer.
WARNING
Do not operate a machine in need of
maintenance.
Periodic Maintenance
• Inspect sprayer broken or worn parts.
• Inspect tubing, hose, and wiring.
Fuse Replacement
The sprayer contains a 5A fuse next to the
power switch. If a problem should occur and fuse
replacement is necessary, the replacement fuse must
also have a 5A rating. Installing a fuse with a higher
rating can damage the system and could start a fire.
WINTER STORAGE
Proper care and maintenance will prolong the life of
the sprayer.
• Drain all water and chemical out of the sprayer
and clean as described in the "After Use" section
of this manual, paying special attention to pump
and valves. These items are especially prone to
damage from chemicals and freezing weather.
• The sprayer should be winterized before storage
by pumping a solution of RV antifreeze through
the entire plumbing.
Содержание TL50