turck TBEN-LH-8IOL Скачать руководство пользователя страница 2

 
 

 

 

 

 

 

—  This page intentionally left blank    — 

Содержание TBEN-LH-8IOL

Страница 1: ...TBEN LH 8IOL EtherNet IPTM Configuration Guide 1218A ...

Страница 2: ...2 This page intentionally left blank ...

Страница 3: ...4 3 Set IP address using Web server 13 2 5 BOOTP DHCP utility 14 3 TBEN LH 8IOL Controls Reference 17 3 1 Device Overview 17 3 1 1 Dimensions and connector assignment 17 3 1 2 Power connector pin assignment 17 3 1 3 IO connector pin assignment 17 3 1 4 Power supply 18 3 1 5 LEDs 19 3 2 IO data map 21 3 2 1 General overview 21 3 2 2 Input data map 22 3 2 3 Output data map overview 24 3 3 Applicatio...

Страница 4: ...configuration 40 5 TBEN LH 8IOL Configuration with OMRON PLC 41 5 1 Get ready environment 41 5 1 1 Register EDS file 41 5 1 2 Add device to the project 42 5 1 3 Register tag sets 43 5 1 4 The device connection types 43 5 2 Configure TBEN LH 8IOL 44 5 2 1 Configure TBEN LH 8IOL using default connection 44 5 2 2 Configure TBEN LH 8IOL using QC ON connection 45 5 2 3 Configure TBEN LH 8IOL using QC O...

Страница 5: ...ing sign and a signal word that expresses the gravity of the danger The warnings have absolutely to be observed DANGER DANGER indicates an immediately dangerous situation with high risk the death or severe injury if not avoided WARNING WARNING indicates a potentially dangerous situation with medium risk the death or severe injury if not avoided ATTENTION ATTENTION indicates a situation that may le...

Страница 6: ...1W EIP21 EtherNet IP communication adapter v1 01 Network Configurator 3 21 1 4 Feedback about these instructions We make every effort to ensure that these instructions are as informative and as clear as possible If you have any suggestions for improving the design or if some information is missing in the document please send your suggestions to techdoc turck com 1 5 Technical support For additiona...

Страница 7: ...It is factory default position of the rotary switches which is associated with the IP address IP Address 192 168 0 254 Subnet mask 255 255 252 0 Gateway 0 0 0 0 The device has limited functionality in this state DHCP client is active and running use any service to assign IP address Web server is active Some other services are active ARGEE PLC is running The device responds to the PING command as f...

Страница 8: ... requesting an IP address 400 DHCP DHCP client is active and requesting an IP address 500 PGM Device comes up with the last IP address saved in EEPROM IP address is programmable 600 PGM DHCP DHCP client is active and requesting an IP address When IP address is acquired the device transitions to PGM mode 900 Factory Reset Device is reset to the factory default setup Table 2 1 Address Modes 2 3 1 St...

Страница 9: ... is acquired the device disables its DHCP The device saves permanently assigned IP address and transitions to the PGM mode 2 3 5 Factory Reset mode 900 The factory reset mode resets the device back to the factory default setup and deletes all custom data in the device s internal flash The procedure Set address switches to 900 Power up device and wait 10sec Set switches to either static rotary mode...

Страница 10: ...ard and IBTP TURCK Service Protocol With the IBTP protocol extended information such as FW version and operating mode improved scanning are read out of TURCK devices and displayed Setting an IP address F2 Locate device using Wink function F3 Actions menu that resets the device to the factory default or reset network F4 Supports the configuration of PROFINET modules assigning the PROFINET name Clip...

Страница 11: ...IP address transitions to 0 0 0 0 when DCHP server is started The device mode is provided position of the rotary switches composite firmware revision ARGEE loaded program is running and BEEP status of the device if enabled Figure 2 5 Search function 2 4 2 DHCP F6 The device IP address may be assigned using the DHCP server provided by the tool The procedure Search F5 to discover device with address...

Страница 12: ...sitions to 0 0 0 0 Figure 2 7 Device DHCP client active view Highlight device Click Change F2 Assign IP address Click Stop DHCP F6 button Figure 2 8 IP Configuration After the IP address is assigned the device responds with Figure 2 9 IP address assigned ...

Страница 13: ...the device into a browser If you don t know what is current IP address use TURCK Service Tool to discover device Enter password into Login field to get administrator s privilege Figure 2 10 Device Web server Open Network Configuration menu enter new IP address and then Submit If your PC network adapter is set to the same subnet as the device s subnet you are going to see the device which comes up ...

Страница 14: ...he IP address is assigned the device DHCP client becomes disabled The procedure Start Rockwell DHCP server Select network interface Figure 2 12 BOOTP DHCP tool At Tools menu click at Network Settings Figure 2 13 Network Settings menu Enter Mask and Gateway addresses in the Network Settings dialog Figure 2 14 Network Settings view ...

Страница 15: ...15 Enter new IP address in the New Entry dialog Figure 2 15 IP address setup Wait for confirmation assigned IP address appears in the IP Address column Figure 2 16 IP address assignment complete ...

Страница 16: ...16 This page intentionally left blank ...

Страница 17: ...ce connector s assignment power distribution and grounding requirements are as follows 3 1 1 Dimensions and connector assignment Figure 3 1 Connector assignment 3 1 2 Power connector pin assignment Figure 3 2 X1 and X2 connector pinout 3 1 3 IO connector pin assignment Figure 3 3 C0 C7 connector pinout ...

Страница 18: ...h the voltage provided at the supply terminals of the TBEN ATTENTION Connection of Class A devices to Class B ports Loss of the galvanic isolation Only use Class A devices with signals on pin 1 pin 3 and pin 4 at Class B ports The connection of Class A devices with signals on pin 2 and pin 5 leads to the loss of the galvanic isolation ...

Страница 19: ...19 3 1 5 LEDs Figure 3 4 LED assignment Figure 3 5 Module LED behavior ...

Страница 20: ...20 Figure 3 6 IO LED behavior ...

Страница 21: ...21 3 2 IO data map 3 2 1 General overview The default data size of the TBEN LH 8IOL is 292 Byte Input data size 146INT 296 Byte Output data size 148INT Figure 3 7 IO data map overview ...

Страница 22: ...22 3 2 2 Input data map Input data map overview Figure 3 8 Input data map overview Input data map word 0 Figure 3 9 Input data map word 0 ...

Страница 23: ...23 Input data map word 1 Figure 3 10 Input data map word 1 ...

Страница 24: ...24 3 2 3 Output data map overview Figure 3 11 Output data map overview ...

Страница 25: ...25 Output data map word 0 Figure 3 12 Output data map word 0 Output data map word 1 Figure 3 13 Output data map word 1 ...

Страница 26: ...26 Output data map word 2 Figure 3 14 Output data map word 2 Output data map word 3 Figure 3 15 Output data map word 3 ...

Страница 27: ...27 3 3 Application Requirements Figure 3 16 TBEN LH 8IOL application requirements Figure 3 17 TBEN LH 8IOL integration into RSLogix5000 ...

Страница 28: ...28 3 4 IO Link Port Setup 3 4 1 Open Web Server Enter IP address of the deice into Web browser Figure 3 18 Web server ...

Страница 29: ... login NOTE If you forget the password reset the device to the factory defaults 900 Before the reset takes place save all IOL current setup as it will be deleted and set to the factory defaults After the reset the first thing to do is to assign an IP address to the device 3 4 3 Basic Parameter Setup Activate DXP outputs 1 3 5 and 7 by entering yes in the drop down selection dialog If DXP output sh...

Страница 30: ...r Manual for the description of the IO Link master s features and setup The setup made by the Web server is saved in the device permanent memory If the device is reset to the factory default values the custom setup will be lost Figure 3 21 IO Link master setup page ...

Страница 31: ...31 3 4 5 VAUX Control The Vaux1 and Vaux2 power is controlled by the VAUX control Parameters web page Available options are 0 24 VDC 1 switchable 2 off Figure 3 22 VAUX control page ...

Страница 32: ...32 This page intentionally left blank ...

Страница 33: ...tronic Data Sheet or the device configuration file described in the Volume 1 Common Industrial Protocol CIP Edition 3 22 by ODVA The procedure Download TBEN LH 8IOL_R2 7 EDS file from the TURCK web site In the RSLogix5000 menu bar expand the Tools drop down menu and click on the EDS hardware Installation Tool Figure 4 1 Tools menu In the Rockwell Automation s EDS Wizard dialog click at the Registe...

Страница 34: ...click on Ethernet to access a drop down menu Click New Module to open the Select Module Type dialog page Figure 4 3 Add new module Enter the device name in the search area Highlight the device from the list and click Create Figure 4 4 Select Module Type dialog page ...

Страница 35: ...ule setup Click Change to open the Module Definition page Figure 4 6 Use default connection AB TBEN LH 8IOL select INT data format from the drop down menu per Figure 4 6 Click OK to return to previous dialog page Click Apply and OK Follow the dialog to save configuration download and go on line Figure 4 6 Select connection and data format ...

Страница 36: ...s Create a new module as described in the section 4 1 2 Fill in the Name Description and Ethernet Address of the device at New Module dialog page Figure 4 7 New Module configuration Click Change to open the Module Definition page Use TBEN LH 8IOL_QC_ON connection from the Connection Name drop down list and select INT data format at the Size drop down list per Figure 4 8 Click OK to return to the p...

Страница 37: ...8IOL QuickConnect operational time Ready to connect time 100ms time measured from the device power up to the first ARP CIP connection time 10ms NOTE The incoming Ethernet cable is always connected to P1 port P2 port is used for daisy chaining next node if required All daisy chained nodes have to be QC enabled and have unique IP address in the system The QC enabled device does not perform duplicate...

Страница 38: ...scription and Ethernet Address of the device at the New Module dialog page Figure 4 10 New Module configuration Use TBEN LH 8IOL_QC_OFF connection from the Connection Name drop down list and select INT data format at the Size drop down list per Figure 4 11 Click OK to return to the previous dialog page Click Apply and OK at the New Module dialog page Follow the dialog to save configuration downloa...

Страница 39: ...on page Select Module Type Enter Generic in the search area highlight the Generic Ethernet Module and click Create Figure 4 12 Generic module selection page Enter the Name Description and IP Address in the New Module page Select the Input Data INT data format in the Comm Format field Enter the Connection Parameters as seen in the following figure Click OK and download configuration to the PLC Figu...

Страница 40: ...ernet Module and click Create Enter the Name Description and IP Address in the New Module page Select the Input Data INT data format in the Comm Format field Enter the Connection Parameters as seen in the following figure Click OK and download configuration to the PLC Figure 4 14 TBEN QC ON configuration 4 2 3 Generic device and QC_OFF configuration Repeat procedure as described above Enter the Co...

Страница 41: ...nt 5 1 1 Register EDS file Start Network Configurator and get the device and associated tag sets registered Expand EDS File drop down menu in the Configurator menu bar click Install Follow the dialog to install TBEN LH 8IOL_R2 7 EDS file Figure 5 1 Install EDS file menu Expand TURCK Inc Communications Adapter in the Hardware List Window Right click at the TBEN LH 8IOL select Property pop up menu V...

Страница 42: ...to the new EtherNet IP network Select TURCK TBEN LH 8IOL Communication Adapter from the Hardware List Window drag and drop into the new EtherNet IP network Figure 5 3 Add new EtherNet IP adapter Right Click at TBEN to open pop up window and click Change Node Address Assign the device IP address Figure 5 4 Change Node Address ...

Страница 43: ...400 length 296 bytes Figure 5 6 Output data tag 5 1 4 The device connection types The device supports multiple connection types Those named Omron are used for configuration with Omron PLCs Table 5 7 Connection types Explanation of terms Omron Connection used by Omron PLC TBEN LH 8IOL Default connection QC ON Connection enables QuickConnect feature QC OFF Connection disables QuickConnect feature ...

Страница 44: ...register Device List into Register Device List Click at New button to open the Edit Connection configuration page Click at the Connection I O Type selection field drop down arrow Select Omron TBEN LH 8IOL connection The Target Device info is auto populated based on the EDS file definition Enter the Originator Device IO tag sets and connection type as follows Register device Figure 5 8 Edit Connect...

Страница 45: ... TBEN LH 8IOL from the Unregister Device List into Register Device List Click at New button to open the Edit Connection configuration page Click at the Connection I O Type selection field drop down arrow Select Omron TBEN LH 8IOL QC ON connection The Target Device info is auto populated based on the EDS file definition Enter the Originator Device IO tag sets and connection type as follows Register...

Страница 46: ... TBEN LH 8IOL from the Unregister Device List into Register Device List Click at New button to open the Edit Connection configuration page Click at the Connection I O Type selection field drop down arrow Select Omron TBEN LH 8IOL QC OFF connection The Target Device info is auto populated based on the EDS file definition Enter the Originator Device IO tag sets and connection type as follows Registe...

Страница 47: ...ts 0000001600019e750008003a TBEN S2 4IOL https pdb2 turck de us DE products 0000003100008dc50003003a 6 1 2 IO Link slave devices The data sheets configuration files user manuals https www turck us en iolink 2577 php 6 1 3 FLC controller ARGEE https pdb2 turck de us DE products 000000370002b2930005003a IO Link IODDs https pdb2 turck de us DE groups 0000000600003a8a00010023 ...

Страница 48: ... are located nationwide Including all major metropolitan marketing areas For Application Assistance or for the location of your nearest TURCK distributor call 1 800 544 7769 Specifications in this manual are subject to change without notice TURCK also reserves the right to make modifications and makes no guarantee of the accuracy of the information contained herein ...

Отзывы: