Inductive sensor
NI5-EM12-Y1X-H1141
Edition
•
2015-02-13T13:35:06+01:00
1 / 5
Hans Turck GmbH & Co.KG
ñ
D-45472 Mülheim an der Ruhr
ñ
Witzlebenstraße 7
ñ
Tel. 0208 4952-0
ñ
Fax 0208 4952-264
ñ
ñ
www.turck.com
Type code
NI5-EM12-Y1X-H1141
Ident no.
4010301
Rated operating distance Sn
5 mm
Mounting condition
non-flush
Assured switching distance
ð
(0,81 x Sn) mm
Repeatability
ð
2 % of full scale
Temperature drift
ð
± 10 %
Hysteresis
1…10 %
Ambient temperature
-25…+70 °C
Output function
2-wire, NAMUR
Switching frequency
2 kHz
Voltage
Nom. 8.2 VDC
Non-actuated current consumption
ï
2.1 mA
Actuated current consumption
ð
1.2 mA
Approval acc. to
KEMA 02 ATEX 1090X
Internal capacitance (C
i
) / inductance (L
i
)
150 nF / 150 µH
Device designation
É
II 1 G Ex ia IIC T6 Ga/II 1 D Ex ia IIIC T115 °C
Da
(max. U
i
= 20 V, I
i
= 20 mA, P
i
= 200 mW)
Construction
threaded barrel, M12 x 1
Dimensions
52 mm
Housing material
stainless steel, V2A (1.4301)
Material active area
plastic, PA
Max. tightening torque housing nut
10 Nm
Connection
male, M12 x 1
Vibration resistance
55 Hz (1 mm)
Shock resistance
30 g (11 ms)
IP Rating
IP67
MTTF
6198 years acc. to SN 29500 (Ed. 99) 40 °C
Switching state
LED yellow
■
ATEX category II 1 G, Ex zone 0
■
ATEX category II 1 D, Ex zone 20
■
SIL2 as per IEC 61508
■
Threaded barrel, M12 x 1
■
Stainless steel, 1.4301
■
DC 2-wire, nom. 8.2 VDC
■
Output acc. to DIN EN 60947-5-6 (NA-
MUR)
■
M12 x 1 male connector
Wiring diagram
Functional principle
Inductive sensors detect metal objects con-
tactless and wear-free. For this, they use a
high-frequency electromagnetic AC field that
interacts with the target. Inductive sensors
generate this field via an RLC circuit with a
ferrite coil.
We offer special versions for temperatures of
-60 °C up to +250 °C.