17
2019/02
5.2
Fastening the device externally with a mounting bracket
CAUTION
Magnetization of metal in close proximity with the measuring probe
Inaccurate measurements
➤
➤
Mount the sensor measuring probe at least 7 mm away from ferromagnetic material.
NOTE
Non-ferrous materials, such as brass, copper, aluminum, demagnetized stainless steel
or plastic do not impair the function of the sensor.
➤
➤
Loosen the hexagon nut on the thread of the sensor head.
➤
➤
Guide the mounting bracket over the pressure pipe up to the sensor head.
➤
➤
If the mounting bracket has an M18 × 1.5 threaded hole, screw the sensor directly.
➤
➤
Fasten the mounting bracket.
➤
➤
Re-fasten the hexagon nut on the sensor head.
Fig. 9: Mounting the device with mounting brackets (dimensions in mm)
MB-R10
MMB-R10
RB-R10
ø 7.1 [0.28]
32 [1.26]
25.4 [1.00]
7 × 26
[0.28 × 1.02]
11 [0.43]
50.8
[2.00]
50.8
[2.00]