Страница 1: ...Your Global Automation Partner Operating instructions LTX Linear Position Sensors with SSI Interface...

Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Contents...

Страница 3: ...ic signal control 11 4 4 2 Update mode 11 4 4 3 Measuring functions 12 4 4 4 Preferred type LTX M F10 SSI2 GAF1 X3 H1161 Measuring range 12 4 5 Technical accessories 13 5 Mounting 15 5 1 Mounting the...

Страница 4: ...4 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...

Страница 5: ...eath or serious injury WARNING WARNING indicates a potentially hazardous medium risk situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a situation that m...

Страница 6: ...3 H1 1 6 1 F10 Design Design F10 Flat face rod 10 3 mm sensor head made from aluminum R10 Raised face rod 10 3 mm sensor head made from aluminum EF10 Flat face rod 10 3 mm sensor head made from stainl...

Страница 7: ...ogy 49 208 4952 390 Outside Germany please contact your Turck representative Hans Turck GmbH Co KG Witzlebenstra e 7 45472 M lheim an der Ruhr Germany 3 For your Safety The product is designed in acco...

Страница 8: ...evices are not safety components and must not be used for personal or property protection The device must be mounted installed operated parameterized and maintained only by trained and qualified perso...

Страница 9: ...th IP68 protection The devices operate without contact which requires the use of a position ing element approved by Turck see Accessories The devices operate on an absolute basis power outages do not...

Страница 10: ...mechanical feedback is produced in the waveguide This feedback is evaluated in the sensor head and output as posi tion information 4 4 Functions and operating modes The devices have an SSI interface...

Страница 11: ...00 measurements depending on length see also the Update time section can be carried out per second to update the position values In synchronous mode the clock rate for the update depends on the contro...

Страница 12: ...rovides the position information when requested by the controller 4 4 3 Measuring functions Different device variants are available for performing different measuring functions Device type Measuring f...

Страница 13: ...uminum can be used for external mount ing with mounting clamp RB R10 50 8 14 1 50 8 max 52 1 EF R10 6900417 Float positioning element stainless steel specific weight 0 62 kg m for external mounting fo...

Страница 14: ...5 MB R10 6900419 Mounting clamp for sensor head and rod for external mounting with screws 50 8 19 3 12 7 12 2 10 5 50 8 26 2 7 1 RB R10 6900420 Mounting clamp for rod for external mount ing with screw...

Страница 15: ...g the entire measuring length deviation 0 5 mm Fig 5 Side view of LTX R10 with dimensions in mm in design with raised face Fig 6 Design with flat face F10 Housing nut with thread dimensions in mm in F...

Страница 16: ...itioning element Observe a minimum distance of 51 mm between the posi tioning element and sensor head with the piston rod in the retracted position If the mini mum distance cannot be observed sink the...

Страница 17: ...etized stainless steel or plastic do not impair the function of the sensor Loosen the hexagon nut on the thread of the sensor head Guide the mounting bracket over the pressure pipe up to the sensor he...

Страница 18: ...at distances of 1200 mm 5 2 2 Mounting positioning elements for external mounting Maintain a distance of 7 mm between the positioning element and ferrite material Use a spacer if necessary Maintain a...

Страница 19: ...clock rates are recommended depending on the length of the connection cables The clock rate and data frame lengths are set by the master Cable length m Baud rate 3 1 MBd 50 400 kBd 100 300 kBd 200 200...

Страница 20: ...ht range SSI clock signal operational Illuminated in yellow No SSI clock signal detected Illuminated in red No positioning element signal detected Red flashing red green flashing Internal error Green...

Страница 21: ...ipe is undamaged and pressure proof NOTE The system does not have to be depressurized for a fluid cylinder application The sensor head and measuring element can be replaced independently of the pressu...

Страница 22: ...e to Turck 11 1 Returning devices If a device has to be returned please be aware that only devices with a decontamination decla ration will be accepted This is available for download at http www turck...

Страница 23: ...data Operating voltage 7 30 VDC Current consumption 100 mA 15 VDC Short circuit protection Yes cyclic Output function 6 wire SSI Design Design Cylindrical smooth Housing material Metal aluminum black...

Страница 24: ...D101914 2019 02 D101914 Over 30 subsidiaries and over 60 representations worldwide www turck com...