Installing
Fastening the device with mounting bracket externally
18
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
5.2
Fastening the device with mounting bracket externally
NOTICE
Magnetization of metal in close proximity with the measuring probe
Inaccurate measurements
Mount the sensor measuring probe at least 7 mm away from ferromagnetic
material.
NOTE
Non-ferrous materials, such as brass, copper, aluminum, demagnetized stainless
steel or plastic do not impair the function of the sensor.
Loosen the hexagon nut on the thread of the sensor head.
Guide the mounting bracket over the pressure pipe up to the sensor head.
If the mounting bracket has an M18 × 1.5 threaded hole, screw tight the sensor directly.
Fasten the mounting bracket.
Re-fasten the hexagon nut on the sensor head.
MB-R10
MMB-R10
RB-R10
ø 7.1 [0.28]
32 [1.26]
25.4 [1.00]
7 × 26
[0.28 × 1.02]
11 [0.43]
50.8
[2.00]
50.8
[2.00]
Fig. 8: Mounting a device with mounting brackets