Technical features
D301171 - IO-Link master 1108
3-14
IO-Link events
Error codes acc. to PROFIBUS-DPV1
The following channel-specific error codes acc. to PROFIBUS-DP are generated by the IO-
Link master SDPX-IOL4-0001:
Note
The TURCK IO-Link master interprets IO-Link event-diagnostics sent by the device
and displays them as plaintext-diagnostic message in the PLC-software.
Figure 9:
Example for the
interpretation of
IO-Link events
Table 10:
Error codes acc.
to DP
Value (dec.)
Diagnosis
Meaning in IO-Link
Error-Codes (1 to 9 acc. to Norm)
2
undervoltage
Undervoltage at the sensor
4
overload
Overload at the output
5
overtemperature
6
wire-break
– Port-configuration of the master
does not and connected IO-Link
device do not match
– Identification (manufacturer-,
device-ID) of the IO-Link device
failed
– no IO-Link device connected
7
upper limit value exceeded
8
lower limit value exceeded
9
error
Содержание IO-LINK MASTER
Страница 1: ...IO LINK MASTER User Manual...
Страница 7: ...D301171 IO Link master 1108 iv...
Страница 65: ...Connection to a Siemens Step 7 usage of the TURCK example program D301171 IO Link master 1108 4 16...
Страница 75: ...Acyclic data exchange via PROFIBUS DP C2 master and TURCK IO Link DTM D301171 IO Link master 1108 5 10...
Страница 83: ...Guidelines for electrical installation D301171 IO Link master 1108 6 8...
Страница 85: ...Index D301171 IO Link master 1108 7 2...