Overview of the TURCK BL ident® UHF system
D101925 0412 -
BLident®
UHF
2-4
2.5.2
User data areas of the data carrier variants
Overview of the UHF data carriers with Impinj Monza 3 chip
The Impinj Monza 3 UHF data carriers have a UII memory area of 12 bytes.
The
Table 1: “Impinj Monza 3 memory area” page 2-4
describes the data structure of the data carriers.
Table 1:
Impinj Monza 3
memory area
Bank
address
[bin.]
Bank name
Memory
address
[hex.]
Number
of bytes
Comment
10
TID
10
hex
-1F
hex
2
0001 + model number
00
hex
-0F
hex
2
fixed = 1110001000000000
01
UII
20
hex
-7F
hex
12
UII
10
hex
-1F
hex
2
Protocol control bits
00
hex
-0F
hex
2
CRC-16 checksum
00
Reserved
20
hex
-3F
hex
4
Password for memory access
00
hex
-1F
hex
4
Password to deactivate the
memory
Содержание BL IDENT
Страница 1: ...QUICK START GUIDE BL IDENT UHF SYSTEM Sense it Connect it Bus it Solve it...
Страница 4: ...D101925 0412 BLident UHF IV...
Страница 22: ...Overview of the TURCK BL ident UHF system D101925 0412 BLident UHF 2 14...
Страница 40: ...Figure 7 PLC_VISU PIB visualization Start up D101925 0412 BLident UHF 3 18 PLC_VISU visualization tab for PIB...