background image

Contents

4

Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com

Содержание B1N360V-QR20-IOLX3 Series

Страница 1: ...Your Global Automation Partner IO Link Parameters IO Link Version 1 1 B1N360V QR20 IOLX3 Inclinometer ...

Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...

Страница 3: ...ts 5 1 4 Feedback about these instructions 5 2 Notes on the Product 6 2 1 Product identification 6 2 2 Manufacturer and service 6 3 Software Supported IO Link Parameterization 7 4 IO Link Parameters 8 4 1 General parameters 8 4 2 Process input data 9 4 3 Process output data 9 4 4 Standard parameters 10 4 5 Parameters 12 ...

Страница 4: ...Contents 4 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...

Страница 5: ...rous situation of medium risk which may result in minor or moderate injury if not avoided NOTICE NOTICE indicates a situation which may lead to property damage if not avoided NOTE NOTE indicates tips recommendations and useful information on specific actions and facts The notes simplify your work and help you to avoid additional work u CALL TO ACTION This symbol denotes actions that the user must ...

Страница 6: ...m an der Ruhr Germany Turck supports you with your projects from initial analysis to the commissioning of your applic ation The Turck product database contains software tools for programming configuration or commissioning data sheets and CAD files in numerous export formats You can access the product database at the following address www turck de products For further inquiries in Germany contact t...

Страница 7: ...ia FDT DTM e g PACTware with the use of DTM or the IODD Device parameters on request data objects Device parameters are exchanged acyclically and on request of the IO Link master The IO Link master always sends a request to the device first then the device responds This applies when the data is written into the device and also when read from the device On request data objects ORDO enable parameter...

Страница 8: ...O Link Parameters 4 1 General parameters Parameter Content Vendor ID 317 0x13D Device ID 720901 0xB0005 IO Link version 1 1 Bitrate COM3 Minimum cycle time 1 3 ms SIO supported False M Sequence Capability PREOPERATE TYPE_1_V with 8 octets on request data ISDU supported Block Parameter True Data Storage True ProfileCharacteristic ...

Страница 9: ...6 True Integer 18000 18000 Signed 0 35999 Unsigned Process data 2 0 16 True Integer 18000 18000 Signed 0 35999 Unsigned Scale 10 x 1 0 8 True Integer 127 127 Vendor specific 0 0 8 True UInteger 0 3 4 3 Process output data Name Byte Bit offset Bit length Subindex access supported Data Type Value Description Process data output 0 0 8 False UInteger 0 3 ...

Страница 10: ...28 Device Reset 129 Application Reset 130 Restore Factory Settings Data Storage Lock 12 0xC 2 0x2 False read write 0 1 1 Boolean false true Device access locks Vendor Name 16 0x10 0 0x0 True read 0 0 5 String Turck Vendor name Vendor Text 17 0x11 0 0x0 True read 0 0 13 String www turck com Additional manufacturer information Product Name 18 0x12 0 0x0 True read 0 0 24 String B1N36 0V QR20 IOLX3 H1...

Страница 11: ...t offset Bit length Data Type Value Default Description Process Data Input 40 0x28 0 0x0 True read write 0 0 48 Process DataIn Union Process Data Input 40 0x28 1 0x01 True write 0 0 8 UInteger 0x04 Center point teach function for the Z axis Process Data Output 41 0x29 0 0x0 True write 0 0 8 Process Data OutUnion ...

Страница 12: ...ing NaN NaN The parameter Location specific tag contains the description of the location of a profile Device within an application Operating hours counter 72 0x48 0 0x0 True read 0 0 32 UInteger NaN NaN 0 Time in hours during which the device is in operation Filter 256 0x100 0 0x0 True read write 0 0 2 UInteger 0 1 1 Filter function 0 Slow 1 Well balanced Center point 258 0x102 0 0x0 True write 0 ...

Страница 13: ...r the Z Axis via the blinking frequency false Off true On Actual temperature 299 0x12B 1 0x1 True read 2 0 8 Integer 127 127 0 Currently measured temperature in C 40 105 C Maximum temperature 299 0x12B 2 0x2 True read 1 0 8 Integer 127 127 0 Maximum measured temperature in C 40 105 C Minimum temperature 299 0x12B 3 0x3 True read 0 0 8 Integer 127 127 0 Minimum measured temperature in C 40 105 C Pr...

Страница 14: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100027854 2021 03 100027854 ...