260 NORTH ELM STREET, WESTFIELD, MA 01085

NOTE:

ALL UNITS COME STANDARD WITH FACTORY WIRED AQUASTAT, WHICH

CAN BE DISABLE IN THE FIELD IF NOT REQUIRED.

ALL WIRING SHALL MEET ALL LOCAL AND NATIONAL CODE.

FACTORY WIRING

FIELD WIRING

IMPENDENCE PROTECTED

2-SPEED - 2P MOTOR

HEAVY DUTY BEARINGS

WHITE

BLACK
GREEN

GROUND

SCREW

YELLOW

HEYCO

YELLOW

GREEN

BLACK

2-SPEED

SWITCH

RED

WHITE

2

1

OFF

BLAC

K

FROM FIELD

120V 60HZ  LINE

(FUSED CIRCUIT ONLY)

120V/60Hz  LINE

WHITE

WHITE

BLACK
GREEN

GROUND

SCREW

YELLOW

HEYCO

YELLOW

GREEN

BLACK

2-SPEED

SWITCH

RED

WHITE

2

1

OFF

BLAC

K

WHITE

AQUASTAT

AQUASTAT

STANDARD WIRING

STANDARD WIRING WITH AQUASTAT DISABLE

IMPENDENCE PROTECTED

2-SPEED - 2P MOTOR

HEAVY DUTY BEARINGS

FROM FIELD

120V 60HZ  LINE

(FUSED CIRCUIT ONLY)

NOTE:

ALL WIRING SHALL MEET ALL LOCAL AND NATIONAL CODE.

  15.00  

  4.06  

  2.50  

  .50  

  1.49  

  .93  

   .375  

A

A

  16.63  

  .94  

  1.00  

  1.19  

  13 LOUVERS  

  13 LOUVERS  

B

SECTION A-A

  .37  

  65°  

DETAIL B

SCALE 1 : 2

  

A

A

B

Figure 5 

- Wiring Diagram KWM6/KWM11

Figure 6 

- KWM6

Figure 7 

- KWM11

TUR-09866_A

TUR-10172_A

TUR-10171_A

Содержание KWM6

Страница 1: ... 21 32 347mm 13 5 32 334mm 19 32 15mm 4 19 32 117mm 3 15 32 88mm WIRING INPUT INLET 1 2 COPPER TUBING OUTLET 1 2 COPPER TUBING CAT 09853 TUR Figure 1 KWM6 Unit is designed to be mounted under sheetrock for proper fit of the cover Install at least 6 8 above the floor for best performance Unit will fit between standard 16 studs on center For unit dimensions on the KWM6 refer to Figure 1 3 6 For KWM1...

Страница 2: ... NOTE When using mono flo or venturi fittings we suggest placement of a ball valve just after the supply take off and before the return is connected Piping Hot Water Boiler The unit supply line should be taken from the boiler side beyond any flo control valve If the system being used is a gravity flow or cast iron hot water system a separate circuit must be installed Piping Water Heater To install...

Страница 3: ... 10 32 X 1 2 SCREW NYLON WASHER INCLUDED KWM6 RECESSED COVER KWM6 UNIT CAT 09853 TUR KWM11 UNIT KWM11 RECESSED COVER 4X 10 32 X 1 2 SCREW AND NYLON WASHER INCLUDED CAT 09853 TUR 4X 10 32 X 1 2 SCREW NYLON WASHER INCLUDED KWM11 RECESSED COVER KWM11 UNIT CAT 09853 TUR Figure 3 KWM6 Figure 4 KWM11 ...

Страница 4: ...Z LINE FUSED CIRCUIT ONLY 120V 60Hz LINE WHITE WHITE BLACK GREEN GROUND SCREW YELLOW HEYCO YELLOW GREEN BLACK 2 SPEED SWITCH RED WHITE 2 1 OFF BLACK WHITE AQUASTAT AQUASTAT STANDARD WIRING STANDARD WIRING WITH AQUASTAT DISABLE IMPENDENCE PROTECTED 2 SPEED 2P MOTOR HEAVY DUTY BEARINGS FROM FIELD 120V 60HZ LINE FUSED CIRCUIT ONLY NOTE ALL WIRING SHALL MEET ALL LOCAL AND NATIONAL CODE 15 00 4 06 2 50...

Отзывы: