ISSUE
RESOLUTION
F2: Cook Temperature
Low
1. Verify the high-limit thermostat is not tripped.
If high-limit is tripped, reset and allow the oven to warm up.
If high-limit is not tripped, follow the instructions below.
High-limit thermostat is not tripped.
Place a small water load in a microwave/heat-resistant container
(approx. 275 ml) in the oven and place the oven in
TEST MODE
. Press
the
MGTRON
key to actuate the microwave. While holding down the
MGTRON
key, watch the CC and IR temperatures. If either temperature
bounces substantially, there may be a noise (EMI) problem.
To correct this problem, examine the wire routing for each
thermocouple wire. If the wires are routed near any high voltage
components such as the magnetron or high voltage transformers, re-
route the wires. If this does not correct the problem, verify that both
magnetrons are securely mounted. Call Technical Support for further
details at
800.90
TURBO
or +1 214-379-6000
.
23
THE CONTROL SYSTEM
Содержание NGC-1007
Страница 2: ...For further information call 800 90TURBO 1 214 379 6000 Accelerating the World of Cooking...
Страница 9: ...Installation Specifications and Maintenance...
Страница 15: ...Theory of Operation...
Страница 19: ...Fault Codes...
Страница 22: ...The Control System...
Страница 34: ...The Microwave System...
Страница 47: ...The Oven Door...
Страница 58: ...The Convection Circuit...
Страница 63: ...IR Element and Catalytic Converter...
Страница 66: ...Schematics and Schematic Components...
Страница 68: ...I O BOARD SCHEMATIC 54 FIGURE 40 I O Control Board and Test Point Locations...
Страница 73: ...F I G U R E 45 NGC Brazil Tornado Schematic NGC BRAZIL SCHEMATIC 63...
Страница 74: ...Service Parts and Illustrations...
Страница 89: ...Comprehensive Part List...