TURBOCHEF TECHNOLOGIES, INC.

Need Ventless? Get Green with TurboChef

ABOUT OUR PATENTED TECHNOLOGY

TurboChef

 

®

 

C3

TM

, i-Series

TM

, Tornado

®

, High h Batch

TM

, HhC 2020

TM

, and HhC 2620

TM

 ovens 

are certified to operate ventless because they function as their own Type I hoods systems. This 

is due to our patented UL-recognized integral recirculating airpath system, which catalytically 

SUBMITTAL RECOMMENDATIONS

1. Determine which agency requires notification,  

  i.e., health, building, or both.
2. Submit the appropriate package for your oven

  type. Submittal packages can be located at    

 

www.turbochef.com/ventless

.

3. Include the following items:

  a. HVAC analysis demonstrating adequate    

    cooling exists to offset the oven’s load.

  b. Your menu, as ventless operation is not  

 

    supported when cooking fatty raw proteins.
If you are unsure of your food type, require 

further assistance, or your request is rejected by 

local authorities and/or jurisdictions, email us at 

[email protected]

scrubs grease and VOCs from the air 

and converts them into CO

2

 and H

2

O. 

As shown in the adjacent illustration, 

blower motors (1) recycle air throughout 

the cook cavity while the air is rapidly 

heated (2) and cleaned by an interior 

catalytic converter (3). On some oven 

models, air is further cleaned by catalysts 

in the vent tube (4) before being emitted 

into the environment. 

With nearly 

125,000 ovens installed worldwide, our 

ventless technology has been tested  

and proven.

HOW THE OVENS ARE TESTED

TurboChef ovens are evaluated according to UL. The evaluation entails placing the test oven 

in an environmental chamber built to capture all emissions escaping during idle, cooking, and 

door-open conditions. During the eight-hour

test period, a typical worst-case food item is cooked 

continually, and 100% of condensable and non-

condensable emissions from the product are 

collected and analyzed according to the 

EPA 202 Test Method. At the conclusion 

TEST POINT

HOODS WASTE ENERGY

Why is ventless operation so important? 

Because hoods consume extra energy, drive up 

utility and installation costs, and restrict the 

ability to install the oven in a location that 

best suits your needs. Existing building HVAC 

is the most economical and environmentally-

friendly way to offset sensible and latent heat 

loads produced by equipment ranging from 

copy machines to light-duty ovens, such as 

the ones produced by TurboChef. As shown 

below, TurboChef ovens are well below the 

EPA, NFPA, and UL limit for emissions 

requiring a vent hood.

of the test, the total concentration of 

particulate matter (emissions) must be 

less than 5.0 mg/m

3

 for the oven to be 

certified for ventless operation. Cooking 

devices that measure above the 5.0 mg/m

3

threshold are considered to produce grease

and must be installed under Type I 

ventilation, according to International 

Mechanical Code.

TM

OUR VENTLESS OVENS

The TurboChef C3

TM

, i-Series

TM

, Tornado

®

, High h Batch

TM

, HhC 2020

TM

, and HhC 2620

TM 

 ovens 

are certified for ventless operation according to Underwriters Laboratories

®

.

©2008-2013 TurboChef Technologies, Inc.

DOC-1118 / Revision C / May 2013

*Ultimate ventless allowance is dependent upon AHJ approval, as some jurisdictions may not recognize the UL® certification or application.

The HhC 2020 and HhC 2620 Conveyors may require installation of additional fire duppression equipment at the discretion of local authorities or jurisdictions.

0

1

2

3

4

5

6

7

8

HhC 2020

HhC 2620

Encore

Sota

Tornado

i3

i5

HhB

C3

Emissions (mg/m

3

)

5.0 mg/m

3

 = EPA, 

NFPA, and UL Limit

8 hours

(180 pizzas)

8 hours

(190 pizzas)

8 hours

(240 pizzas)

8 hours

(160 pizzas)

8 hours

(160 pizzas)

8 hours

(280 pizzas) 8 hours

(272 pizzas)

8 hours

(576 pizzas)

8 hours

(480 pizzas)

8 hours

(1,700 sub-style 

sandwiches)

Vent hood required

Содержание HHC-2020

Страница 1: ...less Label 2 1 Notice of Authorization to Apply to UL Mark Pizza 3 1 Emissions Test Results Pizza 4 1 Notice of Authorization to Apply to UL Mark Sandwiches 5 1 UL Listing 6 1 UL KNLZ Explained 7 1 Tu...

Страница 2: ...he High h Conveyor 2020 offers high heat transfer rates for accelerated cooking a small enough footprint to fit virtually any application and does not require the energy consumption and higher HVAC ne...

Страница 3: ...TS Height 17 0 432 mm Width 48 3 1227 mm Depth 35 7 907 mm Weight 195 lbs 88 5 kg Cook Chamber Baking Area 2 8 ft2 0 26 m2 Belt Length 48 3 1227 mm Belt Width Single 20 508 mm Belt Width 50 50 Split 9...

Страница 4: ...432 mm 4 0 102 mm 60 1 1527 mm with extensions 43 0 1092 mm 30 0 762 mm 35 7 907 mm 48 3 1227 mm 8 5 216 mm 13 0 330 mm 17 0 432 mm 4 0 102 mm 60 1 1527 mm with extensions 4 109 3 762 35 7 907 mm 48 3...

Страница 5: ...13 0 330 mm 13 0 330 mm 8 5 216 mm 13 0 330 mm 21 5 546 mm 8 5 216 mm 13 0 330 mm 34 5 876 mm 13 0 330 mm 43 0 1092 mm 30 0 762 mm 13 0 330 mm 13 0 330 mm 13 0 330 mm 13 0 330 mm 13 0 330 mm 8 5 216...

Страница 6: ...to the Ventilation Recommendations Set Forth by NFPA96 Using EPA202 Test Method Commercial Conveyor Oven with Integral Systems for Limiting the Emissions of Grease Laden Air 1 CONFIGURATION HCT 4181...

Страница 7: ...intended authorization to use the UL Mark the addressee must send a copy of this notice to each manufacturing location currently authorized in File E319600 Vol 1 This authorization is effective from t...

Страница 8: ...UL shall not otherwise be responsible for the use of or reliance upon the contents of this letter by anyone UL shall not incur any obligation or liability for any loss expense or damages including inc...

Страница 9: ...NK09276 Date 07 29 2009 Client Model TurboChef Product Tested Conveyor oven HHC2020 Page 4 1 Manufacturer note this section contains UL test data for actual UL compliance testing Testing was performed...

Страница 10: ...8 in Travers Points When numbers are entered into calculator ideal nozzle size will be displayed Enter number here If ideal nozzle size is not available locate nearest number Enter what nozzle size wa...

Страница 11: ...1 122 14 30 1 50 145 125 37 4 9 2 5 30 121 121 14 31 1 1hr 145 319 37 5 0 2 5 29 121 121 15 32 2 10 145 515 37 4 9 2 5 29 121 121 17 33 2 20 145 709 38 5 2 2 6 35 121 121 12 34 2 30 145 905 38 5 2 2 6...

Страница 12: ...40 149 783 42 2 8 3 0 24 121 121 13 35 5 50 149 986 42 3 0 3 2 24 121 121 14 35 5 5hr 150 197 42 3 1 3 0 24 121 121 14 35 6 10 150 405 42 5 4 3 0 31 121 122 10 35 6 20 150 613 42 5 5 3 0 31 121 122 1...

Страница 13: ...0 0 mg Bottle 2 Mc 3 5 mg Acetone Blank 0 4 mg Bottle 3 Impinger Contents 4 8 mg Bottle 4 Mn 8 9 mg MeCl Wash 1 0 mg Bottle 5 MeCl Blank 0 6 mg Bottle 6 Water Blank 1 3 mg Bottle 7 1 05 mg m3 Cs Mn V...

Страница 14: ...is letter will report the results of the EPA202 test For the record the test was conducted using a Turbochef Model HHC2020 conveyor oven cooking a variety of Potbelly s sandwiches as specified by Turb...

Страница 15: ...as described above The cooking cycle was repeated for 8 hours of continuous cooking During the cooking operation it was noted whether or not visible effluents evolved from the air exhaust of the hood...

Страница 16: ...ring the normal cooking operation There was no noticeable amount of smoke accumulated in the test room after 8 hours of continuous cooking The total amount of grease laden effluents collected by the s...

Страница 17: ...must be presented in their entirety and in a non misleading manner without any manipulation of the data or drawings 2 The statement Reprinted from the Online Certifications Directory with permission...

Страница 18: ...ors unless marked Use Copper Wire Only For Power Supply Connections Commercial cooking appliances of certain types are designed for permanent connections to water supply and sewer lines at the point o...

Страница 19: ...on Designs and or Listings files must be presented in their entirety and in a non misleading manner without any manipulation of the data or drawings 2 The statement Reprinted from the Online Certifica...

Страница 20: ...d 100 of condensable and non condensable emissions from the product are collected and analyzed according to the EPA 202 Test Method At the conclusion TEST POINT HOODS WASTE ENERGY Why is ventless oper...

Страница 21: ...s Warm up 10 14000 0 26 11 83 Cooking 180 9200 3 04 8 83 Snooze 245 4500 2 02 4 75 Idle 285 6750 3 53 0 Total Day 8 84 Yearly Total Month 265 25 3 182 98 HVAC Requirements Per Operating Time Note Appr...

Страница 22: ......

Страница 23: ......

Страница 24: ......

Отзывы: