Convection Circuit
8-10
Blower Motor Controller Fault Codes & Troubleshooting
NOTE:
If no fault condition exists, the LED will be green. If a fault condition exists, the LED will flash
redhen a local keypad is not connected. All faults can be reset by cycling the reset control input,
pressing the stop key, or cycling power, except as noted in the Corrective Action column below.
NOTE: To recycle power, disconnect power for a full minute, or until the LED extinguishes, before
reapplying power.
Reliance Blower Motor Controller Fault Codes & Troubleshooting
# of
LED
Flashes
Fault
Description
Fault Cause
Corrective Action
2
Control Input
•
Illegal control input sequence
•
3–wire: Verify Start and Jog inputs
are not both ON
•
2–wire: Verify that only one input
(Forward, Reverse, or Jog) is ON
2
Function Loss
•
Start attempt while STOP
(function loss) input is off
•
Verify STOP (function loss) input
is ON before attempting to start
drive.
3
Under Voltage
•
Low input line
•
Temporary loss of input line
•
Check input line to verify voltage is
within operating specifications
4
Over Voltage
•
High input line
•
Decel time too fast
•
Overhauling load
•
Check input line to verify voltage is
within operating specifications
•
Increase decel time
5
Drive Overload
•
Excessive driven load
•
Reduce the load
5
Motor Overload
•
Excessive driven load
•
Verify P-02 is set correctly
•
Reduce the load.
•
Check for mechanical binding
6
Over Temperature
•
Operating environment is too hot
•
Fan is blocked or not operating
•
Excessive driven load
•
Verify the ambient temperature is
<50ºC
•
Verify clearance above/below
drive
•
Check for fan obstruction. Replace
if necessary
•
Reduce the carrier frequency (P–
64)
•
Reduce the load
7
Over Current
(300%)
•
Shaft rotation blocked
•
Excessive driven load
•
Output wiring is incorrect or
shorted
•
Check for obstructions to shaft
rotation or reduce excessive load
•
Increase accel/decel time
•
Verify output wiring is correct
8
Bad Keypad
Connection
•
Bad connection from keypad to
drive
•
Verify keypad is properly
connected to drive
•
•
Содержание C3/C
Страница 2: ......
Страница 3: ...TurboChef Technologies Inc C3 This page intentionally left blank ...
Страница 4: ...TurboChef Technologies Inc This page intentionally left blank ...
Страница 12: ...vi SAVE THESE INSTRUCTIONS ...
Страница 14: ......
Страница 15: ...CHAPTER 1 INSTALLATION SPECS ...
Страница 18: ......
Страница 19: ...CHAPTER 2 CLEANING OPERATING ...
Страница 21: ...CHAPTER 3 THEORY OF OPERATION ...
Страница 27: ...CHAPTER 4 FAULT CODES ...
Страница 30: ......
Страница 31: ...CHAPTER 5 TEST ...
Страница 35: ...CHAPTER 6 ELECTRICAL CONTROLS SYSTEM ...
Страница 45: ...CHAPTER 7 COOK DOOR ASSEMBLY ...
Страница 50: ...TurboChef Technologies Inc C Series 7 8 Figure 7 3 Interlock Placement Differences C3 AB vs C3 C ...
Страница 52: ......
Страница 53: ...Cook Door 7 9 Figure 7 58 Interlock Switch Adjustment ...
Страница 56: ...TurboChef Technologies Inc C Series 7 12 FIGURE 7 6a C3 C C3 Cmulti Left Side ...
Страница 64: ...TurboChef Technologies Inc C Series 7 21 Figure 7 9 C3 AB and C3Multi Door Assembly ...
Страница 66: ...CHAPTER 8 CONVECTION CIRCUIT ...
Страница 67: ......
Страница 74: ......
Страница 83: ...This page intentionally left blank ...
Страница 84: ......
Страница 85: ...CHAPTER 9 MICROWAVE CIRCUIT ...
Страница 88: ...TurboChef Technologies Inc C Series 9 4 ...
Страница 91: ......
Страница 94: ......
Страница 97: ......
Страница 98: ...TurboChef Technologies Inc C Series 9 11 Waveguide Components Figure 9 6 Waveguide Assy ...
Страница 101: ...CHAPTER 10 I O Board Schematics ...
Страница 102: ...TurboChef Technologies Inc C Series 10 2 ...
Страница 103: ...10 5 ...
Страница 104: ...TurboChef Technologies Inc C Series 10 4 ...