background image

 

4

TCM-060 

 

MAINTENANCE AND STORAGE 

 
Be sure to unplug the humidifier from the electricity supply before any cleaning, maintenance 
and filling water. 
 
1. 

Clean the water tank. 
Cleaning is suggested at least once every 2-3 weeks. 
Lift the water tank, and turn it over. Take out the water inlet knob, use a piece of soft 
cloth to wipe off stains and water furring in the tank, then rinse with clean water. 

2. 

Clean the water channel and the transducer. 
Cleaning is suggested at least once every 1 or 2 week. But if there is water furring in the 
channel or on the transducer, immediate cleaning is required. The special detergent 
supplied with the humidifier can be used to remove water furring. At first, put 2-3 drops 
of detergent on the transducer. After 1 minute, scrub it with a soft brush. Then rinse it 
with clean water and wipe it dry with a piece of soft cloth. 

3. 

Storage 

 
For storage, clean the humidifier carefully as instructed. After it is dry put it in the 
box and keep in a cool dry place. 
 
 

TECHNICAL DATA 

 

Model No. 

Input voltage 

Power 

Water 

capacity 

Maximum 

evaporating 

TCM-060 

Humidifier: DC24V, 650mA 

Transformer: 100V-240V, 50/60Hz 

16W 

0.6L 

120ml/H 

 
 

CIRCUIT DIAGRAM 

 

 
 
 
 
 
 
 
 