4
TCM-060
MAINTENANCE AND STORAGE
Be sure to unplug the humidifier from the electricity supply before any cleaning, maintenance
and filling water.
1.
Clean the water tank.
Cleaning is suggested at least once every 2-3 weeks.
Lift the water tank, and turn it over. Take out the water inlet knob, use a piece of soft
cloth to wipe off stains and water furring in the tank, then rinse with clean water.
2.
Clean the water channel and the transducer.
Cleaning is suggested at least once every 1 or 2 week. But if there is water furring in the
channel or on the transducer, immediate cleaning is required. The special detergent
supplied with the humidifier can be used to remove water furring. At first, put 2-3 drops
of detergent on the transducer. After 1 minute, scrub it with a soft brush. Then rinse it
with clean water and wipe it dry with a piece of soft cloth.
3.
Storage
For storage, clean the humidifier carefully as instructed. After it is dry put it in the
box and keep in a cool dry place.
TECHNICAL DATA
Model No.
Input voltage
Power
Water
capacity
Maximum
evaporating
TCM-060
Humidifier: DC24V, 650mA
Transformer: 100V-240V, 50/60Hz
16W
0.6L
120ml/H
CIRCUIT DIAGRAM