background image

 

15 

Problem Solution 

FAQ

  

Fault 

Possible Cause 

Solution 

The display does not light 

up. 

Burnt fuse. 

Check the protection fuse on 

the power voltage. 

Check that the power 

voltage is present and 

compliant with that required 

for the device (terminals 1, 

2 and 3). 

The outputs are not 

activated. 

Incorrect output voltage. 

Wiring to solenoid valves. 

Check that the unit and 

solenoid vale output voltage 

agree. 

Check wiring between 

sequencer and solenoid 

valves. 

Do alarm messages appear? 

 

Check the alarm code with 

the table. 

Do the alarms fail to 

activate signalling devices? 

System wiring errors. 

No power to alarm devices. 

The alarm devices must be 

powered by voltage external 

to the sequencer. Activating 

to open the respective relay. 

The sequencer resets 

occasionally 

Check the there is no 

filtered pulse load on the 

power line (spot welding 

machines, welding 

machines, plasma cutters 

etc.). 

Install a filter on the power 

line of the sequencer, if 

needed. 

 
 

 

Содержание E1T 16

Страница 1: ...T USER MANUAL 01 03 2016 Manual Release 1 24 Hardware Release 1 3 TURBO s r l Electronic Control Systems for Dust Collectors e mail info turbocontrols it web www turbocontrols eu TEL 39 0 362 574024 F...

Страница 2: ...e IK07 2 Joule EN62262 Performance Of The Device LED display with 7 segments 3 digits 0 8 each Operating times expressed in seconds with selectable ranges for any application Power supplier 115 230 Va...

Страница 3: ...ally closed The activation of a solenoid valves causes them to open and consequently let out a jet of air Alarm Relays The alarm relays has two voltage free contacts on terminals 4 5 Relay 1 and 6 7 r...

Страница 4: ...oned in a place easily accessible Before working on the equipment to perform any operation switch off the magneto thermic differential switch For electric operations always remove voltage wait 30 seco...

Страница 5: ...correct use of the device may cause damage to the device or to the devices connected to it Furthermore incorrect use or tampering with the device may cause injury Waterproofness of the casing is guara...

Страница 6: ...o select and then and increase or decrease the values The OK button is used to confirm data and reset alarms If the button is pressed during ordinary operation the activity hour meter is displayed The...

Страница 7: ...ping the fan Possible values 01 99 step 1 Default 01 F14 Post cleaning mode pause time fan off Possible values 001 999 step 1 Default 010 F15 Maintenance frequency expressed in tens of hours e g 1 10h...

Страница 8: ...detected To use 115V valves switch the device off and move the output voltage selection jumper to 115V If the jumper is in the correct position press OK then SET select the F05 function with and set 1...

Страница 9: ...ing pages will then appear OFF if the enabling contact is open 14 15 0 if the enabling contact 14 15 is closed and the fan is off Operative Mode The device works as a programmable cycle sequencer The...

Страница 10: ...9 Connection Diagram...

Страница 11: ...Maintenance interval has been reached If one of these occurs the relay is activated Terminal Table Terminal n Description Terminal n Description 1 Power supply 115 230 Vac 32 Solenoid 2 output 2 Powe...

Страница 12: ...11 Jumper Configuration Power Input 115 230 VAC 115 VAC 230 VAC Jumper Configuration Output 115 VAC 230 VAC 24 VAC 24 VDC...

Страница 13: ...12 Installation Casing Dimensions 4 8 Outputs Weight 1 8 Kg...

Страница 14: ...13 Installation Casing Dimensions 12 16 Outputs Weight 2 1 Kg...

Страница 15: ...of cycles after fan stop 1 F14 Pause time between solenoid valves in cycle with fan off 010 F15 Maintenance frequency in 10h 1 10h 100 1000h 100 F16 Maintenance deadline alarm on 1 or off 0 0 F17 Main...

Страница 16: ...d vale output voltage agree Check wiring between sequencer and solenoid valves Do alarm messages appear Check the alarm code with the table Do the alarms fail to activate signalling devices System wir...

Страница 17: ...Product Options All Complies with the following directives Electromagnetic Compatibility Directive 2014 30 EU meeting EU harmonised standards EN61000 6 2 2005 class B of Standard EN61000 6 4 2001 Low...