U s e A n d M a i n t e n a n c e I n s t r u c t i o n s
C h a r g e D i s p l a c e m e n t P r o b e E 9 T r b F o r D u s t C o n t r o l
I n M n 2 5 S T S C
e n R e v . 0 0
T U R B O s . r . l .
D u s t F i l t e r C o m p o n e n t s
V i a P o 3 3 / 3 5 2 0 8 1 1 C e s a n o M a d e r n o ( M B ) I t a l y T e l + + 3 9 0 3 6 2 5 7 4 0 2 4 F a x + + 3 9 0 3 6 2 5 7 4 0 9 2
7
Pro b e I n st al l at io n W i t h Lo ng S t e m A n d St e m Is o l at e d V er si o n
1 C o l l a r F o r T h e F a s t e n i n g O f T h e E l e c t r o d e
2 S u p p o r t F o r P r o b e E l e c t r o d e M a d e O f T e f l o n T o F i x O n T h e C o n d u c t
3 S u p p o r t F o r P r o b e W i t h S l e e v e T o B e F i x e d O n T h e C o n d u c t
4 C o n t i n u o u s W e l d i n g O n S l e e v e C i r c u m f e r e n c e
5 ¾ " G a s T h r e a d e d S l e e v e
Support the electrode of the probe in the longer versions of 500 mm, as
described in the assembly drawing, it is recommended to avoid damage and
breakages.
The support for the electrode must be made in material plastic insulating, the
electrode does not be in contact with metallic parts that alter the measurements.