background image

6

TROUBLESHOOTING

S

N

O

I

T

U

L

O

S

S

E

S

U

A

C

S

M

O

T

P

M

Y

S

Product freezing

Not working
- compressor and 

light not on

Refrigerator not 
cooling well

Noisy

Moisture on exterior of
cabinet

Moisture on interior of
cabinet

Door does not close
correctly

• Turn temperature control to

normal.

• Rearrange product, due to close

to fan.

• Turn temperature control to

normal.

• Check power by plugging power

cord into another outlet that has
power.

• Remove from heat source.

• Remove hot food and allow to

cool.

• Check position of temperature

control.

• Clean condenser.

• Check the refrigerator door.

• Check the installation and insert

the tray correctly.

• Wipe with dry cloth.

• Wipe with dry cloth.

• Keep door closed as ofen as

possible. Wipe with dry cloth.

• Adjust feet under cooler.

• Level unit.

• Reinsert gasket.

The following points are not malfunctions:
• Water-flowing sound can be heard when the compressor stops.

This is a sound of REFRIGERANT flowing.

• When compressor stops by temperature control, it is not out of order.
• This is necessary so ice will not build up on evaporator.
• The door is warm to touch, due to heater that is installed.

• Only a small amount of product

stored in unit.

• Product on top shelf only freezing.

• Temperature of refrigerator below

35˚F.

• Power or electrical failure.

• When the refrigerator is in sunlight

or near a unit that disperses heat.

• When the refrigerator contatins hot

food or too much food.

• When the temperature control is

not set correctly.

• When condenser coil is dirty.

• When refrigerator door is opened

frequently or left open.

• When the installation floor is weak

or the adjustable feet is set
incorrectly.

• When the back-side of the refriger-

ator is close to the wall.

• When the tray is not on the correct

position.

• High-moisture air can produce

dewdrops during the rainy season.

• When food with steam is stored.

• When door is opened frequently.

• When door has slant.

• When floor is not level.

• When door gasket comes out of

place.

Содержание TGM-14RV

Страница 1: ...w turboairinc com FEATURE CHART Casters are applied to TGM 14CRV model How to install the caster and caster brake Refer to page 3 SHELF BOTTOM GRILL DOOR ASSEMBLY HINGE UNDER CONDENSER FAN CONDENSER A...

Страница 2: ...rigerator to make noise Avoid places that are exposed to smoke The discoloring can occur to the refrigerator Set the front of the refrigerator a little bit higher than back side by using adjustable fe...

Страница 3: ...e caster in rear side and the caster brakes in front side by using caster wrench 2 Use the caster shims to level the cabinet if necessary by inserting them to stems of the casters ROTATION CASTER WITH...

Страница 4: ...cuum cleaner Especially be sure to clean the condensor before reoperating after a long period of non operation Check points after cleaning Check again the refrigerator for safety Do not plug the power...

Страница 5: ...g it Warning Warranty will be voided if the following is found Low voltage to unit Should be 115V 60Hz Power cord should not be more than 7 feet long from plug in connection to compressor Multiple uni...

Страница 6: ...en the compressor stops This is a sound of REFRIGERANT flowing When compressor stops by temperature control it is not out of order This is necessary so ice will not build up on evaporator The door is...

Страница 7: ...base holder from the lamp base After the work is done up to this stage the shelves can be adjusted into new position Seprate the lamp from the lamp socket and replace with the new lamp Please turn off...

Страница 8: ...r shipment from manufacturer Compressors determined by Turbo Air have been defective within this extended time period will at Turbo Air s option be either repaired or replaced with a compressor or com...

Страница 9: ...use accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLIE...

Страница 10: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...

Отзывы: