3

Turbo air

INSTALLATION OF THE CASTERS

According to model, refer to the assembly position of casters.

TCB-2SD, TBD-2SD, TBB-2SB, TBB-2SG
TCB-3SD, TBD-3SD, TBB-3SB, TBB-3SG

TCB-4SD, TBD-4SD, TBB-4SB, TBB-4SG

※This 

 

picture  is  a  plan  view  of  bottom  cabinets.

CB  is  an  abbreviation  of  the  caster  with  a  brake.
Other  casters  don't  have  a  brake.

TCB-2SD, TCB-3SD, TCB-4SD
TBD-2SD, TBD-3SD, TBD-4SD
TBD-2SB, TBD-3SB, TBD-4SB

Screw(M4xL12) x 4EA

Screw(M4xL12) x 4EA

Draft Tower Assembly

Draft Tower Assembly

Rubber Gasket

Rubber Gasket

DRAFT ARMS TOWERS Installation Schematic Diagram

* Assemble DRAFT TOWER as above drawing.

Содержание TBB-2SB

Страница 1: ...ate this equipment TBD 1SD TBD 2SD TBD 3SD TBD 4SD StainlessSteel TBD 1SB TBD 2SB TBD 3SB TBD 4SB Black Paint TCB 2SD TCB 3SD TCB 4SD Stainless Steel TCB 2SB TCB 3SB TCB 4SB Black Paint TBB 1SB TBB 2S...

Страница 2: ...ine Installation Schematic Diagram 4 Caution IMPORTANT 5 INSTALLATION 7 CLEANING 8 BASIC OPERATION 9 BEFORE REQUESTING SERVICE 10 WARRANTY 11 12 2 Turbo air CONTENTS PAGE The serial number is located...

Страница 3: ...This picture is a plan view of bottom cabinets CB is an abbreviation of the caster with a brake Other casters don t have a brake TCB 2SD TCB 3SD TCB 4SD TBD 2SD TBD 3SD TBD 4SD TBD 2SB TBD 3SB TBD 4S...

Страница 4: ...LINE Installation Schematic Diagram Assemble BEER LINE CO2 LINE as above drawing Distributor Fixture CO2 Line Beer Line 1 Beer Line 2 Beer 1 Beer 2 CO2 TCB 2SD TCB 3SD TCB 4SD TBD 2SD TBD 3SD TBD 4SD...

Страница 5: ...PORTANT On direct draw dispensers the drain is located at the front of the cabinet To plumb in the drain connect 5 8 P V C pipe to the 5 8 barbed fitting supplies with the unit DIRECT DRAW Don t pull...

Страница 6: ...oltage and amperage must be run for connection of the line cord Unplug the unit whenever performing maintenance functions or cleaning the refrigerated cabinet Compressor warranty is void if burnt out...

Страница 7: ...eight of the cabinet and contents 3 DO NOT PLACE NEAR HEAT Be sure to avoid hot corners and locations near stoves High ambient temperature will make cooling efficiency lower 4 INDOOR USAGE ONLY Be sur...

Страница 8: ...grease This will require periodic cleaning Condenser fins should be cleaned at least every three months 90 days or as needed To clean condenser unplug the unit Condenser can be cleaned with vacuum br...

Страница 9: ...y setting maintains about 38 F 3 C inside 3 Set toward counter clock wise warmer temperature and clock wise for colder temperature 4 The thermostat controls compressor s cycling by sensing inside temp...

Страница 10: ...e floor is too weak or the leveling feet are set incorrectly The backside of the unit is too close to the wall High moisture air can produce dewdrops during rainy seasons The door is opened too freque...

Страница 11: ...r charges only and reasonable travel time as determined by Turbo Air Additional Four Year Compressor Warranty In addition to the one 1 year warranty stated above Turbo Air warrants its hermetically se...

Страница 12: ...TH IN THE WARRANTY PACKET PROVIDED WITH THE UNIT ALTERATION NEGLECT ABUSE MISUSE ACCIDENT DAMAGE DURING TRANSIT OR INSTALLATION FIRE FLOOD ACTS OF GOD Turbo Air is not responsible for the repair or re...

Страница 13: ...13 Turbo air 1250 Victoria street CARSON CA 90746 TEL 310 900 1000 FAX 310 900 1077 Toll Free 1 800 627 0032 U S A In Canada http www turboairinc com...