USING THE COMPRESSOR

TOOL CONFIGURATION

100L/MIN OIL - LESS COMPRESSOR

11.

Before starting run through this simple list;

1.   Ensure the compressor is fully assembled
2.   Drain tap – open and drain tank
3.   Drain tap – close fully
4.   Check power lead for any damage. If damaged have 

replaced by an authorised service centre.

5.   Plug compressor into a standard 240V 10Amp AC power 

point and turn ON.

6.   Lift the red button to turn ON, see page 11, Pic.4.
7.   Allow the compressor to fi ll the air tank.
8.   Turn the compressor OFF.
9.   Turn the power point OFF and disconnect the  

power lead from the power point.

10. Connect your air hose and air tools.
11. Reconnect to the power lead to the power point and 

turn ON.

12. Turn your compressor ON.
13. Once turned on and you begin using the connected air 

tools the compressor will start and stop without warning.  

This is controlled by the pressure switch.  These 

pressure settings are factory set and should not be 

changed. 

 

Pumping starts at (minimum) 85PSI and stops at 

(maximum) 115PSI.  Once the initial pump up stage has 

fi nished you can use the compressor. Remember to adjust the 

outlet air pressure to the tools recommended working 

pressure and open the tap fully.

The confi guration of tools and accessories can be varied to 

suit your particular requirements. A basic recommended set 

up is shown in Pic. 6 (accessories not included). 

When you have fi nished using your compressor follow these 

simple steps:

1.   Turn your compressor OFF, using the ON/OFF button.
2.   Turn the power point OFF and disconnect the power 

lead.

3.   Disconnect your air tools and air hose.
4.   Clean your air hose and air tools.
5.   Store your air hose and air tools in a secure well 

ventilated cabinet.

6.   Slowly open the tank drain tap, see page 14. This allows 

excess air and moisture, water, to vent.

7.   Leave the tank drain tap open. This allows any moisture 

to drain while the infl ator is stored.

NOTE: Use of a water trap may be of beni

fi

 t to ensure no 

water or moisture reaches your air tools.

PIC. 6

Содержание TA1500

Страница 1: ... NO TA1500 Read this material before using this product Failure to do so can result in injury SAVE THIS MANUAL Forspare parts or product informationplease email customerservice euroquip co nz Silent portable compressor ideal for general inflating tasks ...

Страница 2: ...SSOR 2 CONTENTS INTRODUCTION 3 COMPONENTS AND CONTROLS 8 OPERATING INSTRUCTIONS 9 STARTING AND STOPPING YOUR COMPRESSOR 10 USING THE INFLATOR 11 TOOL CONFIGURATION 11 TA1500 PARTS LIST 14 TA1500 PUMP PARTS LIST 15 WARRANTY 16 ...

Страница 3: ...nk Displacement 190L min 6 7CFM FAD 7Bar 100L min 3 4CFM Noise 1 5M 70dBa Net Weight 16 4kg INTRODUCTION Dear Customer Thank you for purchasing this Compressor which has passed through our extensive quality assurance processes Every care has been taken to ensure that it reaches you in perfect condition However in the unlikely event that you should experience a problem or if you require any assista...

Страница 4: ...d benches should be kept tidy Cluttered benches and work areas can cause accidents Floors should be kept clean and free from rubbish Special care should be taken when the floor is slippery due to sawdust or wax Always leave sufficient distance at least 5 metres between the Compressor and the work area especially when using tools designed for sanding or spraying liquids WORK ENVIRONMENT Do not expo...

Страница 5: ...ed service facility Keep handles clean dry and free from oil and grease Ensure that ventilation slots are kept clean and free from dust at all times Blocked ventilation slots or air filter can cause overheating and damage to the motor and this will not be covered under warranty DISCONNECT COMPRESSORS Ensure that the compressor is disconnected from the mains supply when not in use before servicing ...

Страница 6: ...l noise may damage your ears Respiratory Protection When operating any machinery that creates dust or when spray painting an approved dust filter mask must be worn When machining concrete man made fibres especially MDF Medium Density Fibre board the resin used in these materials can be hazardous to your health Use an approved face mask with replaceable filter Do Not Over Reach Do not over reach Ke...

Страница 7: ...t type of tool for the operation to be carried out Never use the compressor if any part of the unit is damaged Always have the compressor serviced by an authorised service agent Always wear safety eye ear and respiratory protection when operating the Compressor Allow the tank to completely fill before using the compressor If the compressor makes an unfamiliar sound or vibrates excessively switch t...

Страница 8: ... 1 Pressure switch 2 On Off button red colour 3 Handle 4 Quick Connect Outlet 5 Pump 6 Tank 7 Rubber feet 8 Tank drain tap 9 Tank pressure gauge 10 Air filter 11 10A Plug 12 Air Filter Quieting Tube 13 Outlet pressure gauge PIC 1 3 2 6 7 8 5 1 4 1 9 13 11 12 10 ...

Страница 9: ...r must be used Failure to do so may result in irreparable damage and will void the warranty Pic 3 To install 1 Carefully screw supplied air filter into the threaded hole on the top of the pump head This only needs to be done up by hand Do not use tools to tighten air filter NOTE Do not OVER TIGHTEN as this may damage the air filter or cylinder head which will NOT be covered under warranty Once air...

Страница 10: ...on top of the pressure switch To turn your To turn your CompressorOFF Push down the red ON OFF button on top of the pressure switch RUNNING IN YOUR NEW COMPRESSOR Your compressor does not require running in Before use ensure you have read and understood these instructions Before use ensure this compressor is fully assembled as per page 10 Positioning your new compressor Choose a location away from...

Страница 11: ...ettings are factory set and should not be changed Pumping starts at minimum 85PSI and stops at maximum 115PSI Once the initial pump up stage has finished you can use the compressor Remember to adjust the outlet air pressure to the tools recommended working pressure and open the tap fully The configuration of tools and accessories can be varied to suit your particular requirements A basic recommend...

Страница 12: ...eds to be higher turn clockwise Use the gauge to ensure you set the correct working pressure Note Different air tools require different operating pressures Always check with the tool manufacturer if unsure PIC 7 Tank pressure gauge Regulator Outlet tap Outlet pressure gauge DRAIN TAP Pic 10 After use open the drain tap to drain excess air and any moisture The excess air will also help purge the mo...

Страница 13: ...is sealed Check that the air fitting is not leaking If leaking replace compressor will not start smells like burnt oil Using beyond the 50 duty cycle allow to cool for 30 minutes before reusing this compressor IMPORTANT NOTE This compressor has a maximum pressure of 8 bar Always regulate the air pressure to match your air tool Different air tools require different operating pressures Always check ...

Страница 14: ... 4 3 Capacitance Cover 4 Pump Rubber Screw 5 Capacitance 6 Pressure Switch 4 Way 7 Safety Valve 8 Power Cord 9 Drain Valve 10 Rubber Pad 11 Tank Coated 12 One Way Valve 13 Realease Tube 14 Discharge Tube 15 Outlet 16 Rubber Connect Tube 17 Regulator 18 Gauge 18 Elbow Connector ...

Страница 15: ... Crank Bearing 6006 2Rs Conrod Piston Ring Piston Cover Cylinder Valve Seal Valve Plate Cylinder Head Seal 3 4 5 6 7 8 9 10 11 2 1 Cylinder Head Connect Tube Eblow Connector Fan B Crankcase B Bearing 6203 2rs Stator Rotor Crankcase A Pump Pad 14 15 16 17 18 19 20 21 13 12 ...

Страница 16: ... has been maintained and serviced suitably for a claim to be considered under warranty Failure caused by incorrect operation of the product lack of proper care and maintenance of the product external damage external circumstances such as tions to the product attempted repair service by a party other than an Approved Service Agent is not covered under warranty Warranty does not cover pre delivery s...

Страница 17: ...100L MIN OIL LESS COMPRESSOR 17 ...

Страница 18: ...100L MIN OIL LESS COMPRESSOR 18 ...

Страница 19: ...100L MIN OIL LESS COMPRESSOR 19 ...

Страница 20: ...tomer and will strive to provide you with the best service and reliability in the industry This product is backed by our extensive warranty and service network To locate your nearest distributor or service agency visit www euroquip co nz or email us at customerservice euroquip co nz ...

Отзывы: