Installation and User Manual
D9007050A
User Alert Pager System
Installation
The pager transmitter is driven by the data output from the ‘Printer Port’ of the Control
Card of any type of Haven, Communicall, or Vision system. It is powered from the fused
battery-backed 14V supply provided on the ‘Pager Port’.
The Pager Transmitter should be sited indoors, at roof level, at least 2m away from other
equipment. The following diagram illustrates the wiring interconnections between the
Haven or Communicall Control Card and the Pager Transmitter.
IMPORTANT – if a system printer is also fitted then the printer RTS signal (normally
connected to PBY) MUST be disconnected.
Configuration
No configuration of the Pager Transmitter is required.
If paging on an external fire panel activation is required then this should be implemented
either via a speech module (must be coded to 999), with the fire panel input connected to
the smoke input, or via the fire panel input on the control card. In the latter case, the
system must be configured to generate a 795 call.
Ensure the Scheme Manager and Control Centre Manager are aware of speech module
i.d. changes.
Pager Transmitter
ON
TX
RTS
RXD
Control Card
14V
PDA
PBY
Pager Port
Printer Port
Red
Black
White
Blue
10 core cable
GS013
Printer
Data
RTS
No Connect
F2A
0V
Installation and User Manual
D9007050A
User Alert Pager System
Parameter
Value
Notes
Page 0 - 12
1
Enable printer
Page 0 – 25
32
Page 0 – 26
32
Ensure termination characters set correctly
Page 0 – 36
243
Page 0 – 37
128
Ensure printer baud rate set to 2400
Page 0 – 40
255
Printer busy line set to 0 = busy
Page 0 – 87
255
Ensure DES activity printed (if applicable)
Page 1 - 259 (Communicall only)
7
Page 1 - 259 (Communicall only)
9
Page 1 - 259 (Communicall only)
5
Ensure fire panel input coded to 795
Each Pager Receiver used on the system MUST be coded to the speech module i.d.
number of the resident concerned. This procedure is carried out using a programming kit
(Tunstall part number 9000/70A) and is detailed in Technical Bulletin TB297.
Licensing of Equipment
A licence must be obtained for the pager system from OFCOM – Details can be obtained
from http://www.ofcom.org.uk/
Testing
On application of power, the red LED on the Pager Transmitter will illuminate. The green
LED will illuminate for approximately 2s whilst the Pager Transmitter is transmitting.
In order to test the system, generate all events of interest on the Haven or Communicall
system and check that all the pagers assigned to the system respond appropriately.
User Instructions
Each Pager Receiver is supplied with a comprehensive instruction booklet. Basic user
instructions are provided here, to be carried out with reference to the diagram below.
Selection
Button
Left
Button
Right
Button
Reading
Button