background image

 

D6907021A0 

 

5.

 

The installation must include some form of isolation 
switch to allow for future maintenance work. 
 

6.

 

All necessary care should be taken to ensure that 
the unit cannot be disconnected accidentally. 

 

7.

 

Once connected to the mains the gas detector needs a 
warm-up period of 3-4 minutes, after which the unit will 
work.   

 

DO NOT REMOVE THE COVER FROM THE NATURAL GAS 

DETECTOR WHEN THE DETECTOR IS CONNECTED TO MAINS 

POWER. 

 
 

Pairing the Natural Gas Detector to a Tunstall Lifeline. 

 

1.

 

Place the Lifeline home unit into telecare sensor assign 
mode by pressing the green cancel button until the unit 
beeps and/or announces ‘Programming Mode’, then 
press and hold the green cancel button again until the 
unit beeps, release the cancel button and the unit will 
announce ‘Registration Mode’ . 
 

2.

 

Generate a radio transmission from the Natural Gas 
Detector by placing the magnet (supplied in the box) 
adjacent to the Detector at the point labelled 
“MAGNET”. The Lifeline will announce “Gas Detector” to 
confirm pairing was successful.  

 

Содержание 69005/10

Страница 1: ...is guide is for use with the Natural Gas methane Detector Tunstall part number 69005 10 What is the Natural Gas Detector The Natural Gas Detector has an integrated 869 MHz radio module The unit is mounted on a wall bracket with moulded screw holes The product has been assembled and programmed to simplify installation ...

Страница 2: ... should not be installed close to cooking appliances sinks fans and in areas where environmental conditions differ from those recommended and specified in this document 2 Drill two holes to line up with the key slot holes in the wall mounting bracket securely fit two screws and leave the heads of the screws protruding from the wall for the wall plate to fit onto 3 The Gas detector must be installe...

Страница 3: ...ECTED TO MAINS POWER Pairing the Natural Gas Detector to a Tunstall Lifeline 1 Place the Lifeline home unit into telecare sensor assign mode by pressing the green cancel button until the unit beeps and or announces Programming Mode then press and hold the green cancel button again until the unit beeps release the cancel button and the unit will announce Registration Mode 2 Generate a radio transmi...

Страница 4: ...ing with the Tunstall Lifeline use a certified mixture of sample gas and by verifying that the Lifeline announces and raises an alarm Using a gas bottle with maximum concentration of 25 LEL Methane balanced in air and set the gas flow at 0 5 litre minute max Speciality Gas UK www speciality gases com supplies such gas bottles DO NOT USE THE GAS OF LIGHTERS TO TEST THE OPERATION OF THE DETECTOR AS ...

Страница 5: ...ule will raise a low battery alert at the end of its life When disposing of the Natural gas Detector at the end of its life please follow local disposal advice Important information Important information Important information Important information Please read the manufacture Please read the manufacture Please read the manufacture Please read the manufacturer r r r s s s s manual found within the b...

Страница 6: ...xt of the EU declaration of conformity is available at the following address uk tunstall com approvals uk tunstall com approvals uk tunstall com approvals uk tunstall com approvals tunstall com tunstall com tunstall com tunstall com Our policy of continual development means that product specification and appearance may change without notice 2018 Tunstall Healthcare Group Ltd TUNSTALL and LIFELINE ...

Страница 7: ...D6907021A0 7 This page is intentionally left blank ...

Страница 8: ...nnot be identified or isolated evacuate the building immediately and from outside call the emergency services Should the alarm continue and the cause of the gas Should the alarm continue and the cause of the gas Should the alarm continue and the cause of the gas Should the alarm continue and the cause of the gas leak cannot be identified or isolated evacuate the leak cannot be identified or isolat...

Отзывы: