REAR PANEL 

 
Chassis ground screw: 

The chassis ground screw must be properly connected to the chassis of your vehicle before operating 
the inverter. 

 
Fan(s): 

In order for the inverter to properly operate, the fan(s)  opening must never be obstructed. Allow at 
least six inches of clearance around the inverter for airflow.  All fans are thermostatics  and operate 
upon the interior temperature of inverter. 

 

REMOTE CONTROL

 (Except E-1000) 

 
ON/OFF: 

Your inverter is equipped with one 6 meters jack remote switch. The remote switch allows you to 
mount your inverter out of sight and turn it ON or OFF from a convenient location. The ON/OFF 
switch on the inverter’s front panel must be turned on for the remote to be operational.   

 
Input Voltage: 

By pressing the “SELECT” button until the “INPUT VOLTAGE ” light comes on, the battery voltage 
indicator displays the voltage at the input terminal of the inverter. Usually this voltage is very close to 
the battery voltage and the difference, if any, is caused by the resistance of the cables and 
connections. A regular maintenance will contribute to minimize the possible resistance (see 5).  

 
Output Power: 

By pressing the “SELECT” button until the “OUTPUT POWER” ligh comes on, the watts indicator 
displays the current provided by the inverter in KW. 1 KW = 1000 watts. If you read 1.20, it means 
the inverter is providing 1200 watts.  

 
“FAULT” light: 

An audible alarm will sound announcing a faulty condition such as: low or high battery voltage and 
overload. 

 
“OVERTEMP” light: 

An audible alarm will sound announcing an overtemp condition.  

 

“LVP” on display: 

Indicates the inverter is in Low input Voltage Protection mode (see 4.3).  

 

“OLP” on display: 

Indicates the inverter is in High input voltage Protection mode or if your consumption exceeds the 
nominal capacity of the inverter (see 4.3).  

3

 

Permanent Installation 

 
The use of the Tundra International installation kits  is strongly recommended. 

These  complete installation kits  are  custom 

designed to maximize performance. It has been developed to promote safe installation and to help eliminate the difficult task of 
sourcing  the requisite and right material. 

 

3.1

 

Recommended material                  

E-1000 

   HD-1200         HD/HDI-1800 

   HD-2500 

HDI-3000 

 

 E-1500 

   E-2000 

-

 

Tundra CM series installation kit                CM1000   CM1200/1500    CM1800/2000         CM2500             CM3000 

Or 
-

 

Welding  cable                                                 AWG #4      AWG #2 

  AWG #1/0 

 AWG #2/0 

AWG #3/0 

-

 

Battery copper cable No. 8 AWG 

-

 

PVC strain relief for flexible cable                       ½” 

   ½” 

     ¾” 

  ¾” 

1” 

-

 

6 Tin plated terminal lugs  

 

 

 

-

 

CNL fuse block 

-

 

CNL fuse                                                             100A 

    150A 

    200A 

 250A                  300A  

-

 

Plastic « loom » tubing  

-

 

Heavy duty AC power distribution center 

-

 

Red and black heat shrinkable tubing 

-

 

Plastic cable ties 

-

 

Clamps and bolts 

Содержание CM Series

Страница 1: ...Owner s guide E 1000 E 1500 E 2000 HD 1200 HD 1800 HD 2500 HDI 1800 HDI 3000 Install using Tundra CM Series installation kit Ask your retailer See page 4 for details www tundrainternational com ...

Страница 2: ... 3 6 1 Preparation of the cable connected to the positive end 6 3 6 2 Preparation of the cable connected to the negative side 7 3 7 Connecting the Inverter 7 3 8 Connection of the batteries 8 3 8 1 Positive Terminal 8 3 8 2 Negative Terminal 8 4 OPERATION 8 4 1 Trouble loads 8 4 2 Microwave 9 4 3 Operating limits 9 5 MAINTENANCE 9 6 TROUBLESHOOTING 9 6 1 Television and CB radio interference 9 6 2 ...

Страница 3: ...ter is regulated to 120 volts and its waveform is called a Modified Sine Wave It is a stepped waveform suitable for most AC loads designed to have characteristics similar to sine waves delivered by utility power Note that our modified sine wave output power is much more efficient than the square wave generated by other inverters on the market today The modified sine wave generated by your inverter...

Страница 4: ...ts indicator displays the current provided by the inverter in KW 1 KW 1000 watts If you read 1 20 it means the inverter is providing 1200 watts FAULT light An audible alarm will sound announcing a faulty condition such as low or high battery voltage and overload OVERTEMP light An audible alarm will sound announcing an overtemp condition LVP on display Indicates the inverter is in Low input Voltage...

Страница 5: ...in fire if exposed to flammable vapors WARNING This equipment contains components that tend to produce arcs or sparks To reduce the risk of fire or explosion do not install in a compartment containing batteries or flammable materials or in a location that requires ignition protected equipment Close to batteries Install the inverter as close as possible to the batteries but not in the same compartm...

Страница 6: ...ratures in excess of 215 Fahrenheit As included in our CM series kits we recommend welding cables as the best size type for connection between the batteries and your inverter Keep the cable length as short as possible no longer than 12 feet This will ensure that the overall system efficiency is as high as possible and will keep the voltage drop between the batteries and the inverter to a minimum I...

Страница 7: ...ing the necessary length to allow movements due to the suspension of the cabin Strip approximately a half inch of insulation from the two ends of the cable insert the cable through the second PVC strain relief and install good quality tin plated terminal lugs on the stripped sections Crimp the terminals with a hand held crimping tool the use of a locked plier Vice Grip is not recommended until the...

Страница 8: ...will permanently damage your inverter THIS IS NOT COVERED BY THE WARRANTY 3 8 1 Positive Terminal Always connect the positive terminals before the negative Plug the small section of the cable connected to the positive terminal of the inverter to the positive terminal of the battery by solidly fixing the terminal with the nut Without tightening them too much the terminals must not be able to move a...

Страница 9: ...ut down if the voltage exceeds 15 volts or if your consumption exceeds the nominal capacity of the inverter The OLP code will be displayed on the remote This protects the inverter from excessive input voltage While the inverter incorporates protection against over voltage it may still be damaged if the input voltage exceeds 16 volts 5 Maintenance Very little maintenance is required to keep the inv...

Страница 10: ...idate their fonctionality Remove or reduce load switch the inverter OFF at least 5 second and restart the inverter No output voltage Inverter off No DC power to the inverter Reverse DC polarity Turn the inverter on Check the wiring Check battery fuse et check the installation before changing it Replace internal fuses of the inverter Damage caused by reversed polarity is not covered by the warranty...

Страница 11: ...without notice 8 Limited one year warranty Tundra International Inc warrants its power inverters against defects in workmanship and materials for a period of one 1 year from the date of first consumer purchase This warranty is given only to the first end use purchaser of the product This limited warranty is void if the unit is abused modified installed improperly if the housing has been removed if...

Страница 12: ...ORTED DEFECTIVE UNIT MAKE SURE THE UNIT HAS BEEN INSTALLED PROPERLY AS RECOMMENDED IN OUR USER S GUIDE PLEASE CONTACT US AT 450 649 2470 OR 1 877 964 2582 FOR A RETURN AUTHORIZATION NUMBER Customer s Name Consumer Purchase Date Model Serial Number DESCRIPTION OF THE PROBLEM The above information along with the proof of the consumer s purchase date such as the duplicate of the receipt must be inclu...

Отзывы: