Installation
Paper Mold
Ceiling
Socket
DN
DN
DN
DN
Screw Hole
Screw Hole
Side Wall
Fig. A
Cooking
Equipment
Cooking area
Do not install above or
inside this area
S
hort Circuit or Electric Shock Hazard:
D
o not mount in places with excessive moisture.
D
o not install the product near the shower room or above the bath
tub in the bathroom or near places where it gets wet or immersed
in water easily.
D
o not spray water directly on this device.
P
ossible damage:
D
o not mount over heating sources such as cooking equipment
(see Fig. A), or in places with temperatures over 40
℃
.
45°
45°
1
-
-
-
2
-
P
ossible damage or fire :
D
o not use power sources outside the rated voltage.
D
o not use alternative mounting methods other than what is
instructed in this manual.
R
isk of Electric Shock Due to Inadequate Wiring :
A
ny alteration to the internal wiring in this device is not allowed. In
case of failure, please contact the service station.
I
f the power cord is damaged, it must be replaced by the
manufacturer, the manufacturer’s service station, or a qualified
person to avoid danger.
3
-
4
5
-
-
T
o Prevent Accidents :
T
he bottom of the unit must be installed 2.3 meters or more above
the ground.
N
o water pipes are allowed to pass through above the product
and 2 m around it.
I
n case of gas leakage, Do Not turn on this device.
T
his device shall not be operated or maintained by children or
inexperienced individuals.
T
his device must not be mounted in places with peculiar smell or
hazardous gas to prevent undesirable gas from flowing backwards
into the room.
T
he outdoor part of the device must be mounted with the provided
accessory: rain hood.
(for EU region)
T
his appliance can be used by children aged from
8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they
have been given supervisionor instruction concerning use of the
appliance in a safe way and understand the hazards involved.
(for EU region)
C
hildren shall not play with the appliance.
(for EU region)
C
leaning and user maintenance shall not be
made by children without supervision.
(for other than EU region)
T
he appliance is not to be used by
persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction.
(for other than EU region)
C
hildren being upervised not to play
with the appliance.
6
-
-
-
-
7
8
9
10
11
12
13
WALL
WALL
Panel
Drive the yellow plastic anchor into the screw hole posit5-2
Disassemble the panel, align it with the plastic anchors and tighten
it by screws.
Assembly of exhaust duct
Please confirm whether the product will be subjected to direct wind
and rain. If that is the case, a commercially available 4 inches rain
cover is recommended to be installed at the pipe outlet.
Drill the hole with 3~5 degree angularity to the wall.
1
2
External Air Inlet Filter (Disposable PM2.5 filter)
●
●
Pre-Filter (Washable filter)
●
●
●
Clean the pre-filter once every two weeks is recommended.
Take off the buckle then pull out the PM2.5 filter and pre-filter.
Wash and clean the pre-filter. Ensure that it is completely dry
before refitting. Restore the buckle
.
If the panel indicator light shows RED, replace the PM2.5 filter.
Take off the buckle, after replacing the filter, restore the buckle.
On the remote control, press the RESET key.
Turn the power off before cleaning or maintaining the product.
Instructions Download :
w w w . s u n o n . c o m
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO.,LTD.
WALL MOUNTING (Cement wall)
CEILING MOUNTING (Light steel joist ceiling)
Take out the paper mold from the box, draw an installation hole
and screw holes on the wall as the below figure shows.
The installation hole cannot be opened on crossbeams,
pillars, or bearing walls. This will endanger the building’s
structure. It must also avoid electric wires inside the wall.
1
A distance of 15 cm or more is required from the edge of
the paper mold to the ceiling and each side of the wall.
The socket needs to be within 30cm of the device,
otherwise an extension cord is required.
Use a wall drill to open up a Ø110mm on the mounting hole
position; and a Ø6mm, 30mm deep screw hole on the screw hole
position.
WALL
WALL
WALL
WALL
●
●
2
The direction of wall drilling shall be inclined 3~5 degrees to
the wall.
If the drilling position is around area, please consult the
professional technician to use if any other reinforcement
work is required, such as waterproofing.
Take out the unit and the waterproof gasket, tear off the adhesive
back of the waterproof gasket, and stick it on the vent of the unit.
2
Connect the adapter ring to ductwork with waterproof tape tightly.
3
Adapter ring
Take out the unit and the waterproof gasket, tear off the adhesive
back of the waterproof gasket, and stick it on the vent of the unit.
Connect a 4 inches round duct to adapter ring and sealing it with
waterproof tape.
Connect the adapter ring to ductwork with waterproof tape tightly.
4-1
4-2
3
Adapter ring
Round duct
Waterproof tape
Waterproof tape
Waterproof tape
Waterproof tape
Washer
Nut
5-1
5-2
Take off the ceiling from the light steel joist ceiling.
Take out the paper mold from the box, draw an installation hole
and screw holes on the ceiling as the below figure shows.
Cut a Ø105 mm mounting hole on the ceiling, and drill a Ø6mm
through hole at the screw hole point.
1-1
1-2
1-3
Disassemble the panel, align it with the screw hole
Secure the unit to the ceiling with suitable hardware.
(We recommend M5x30L screws)
Assemble the panel.
4-1
4-2
4-3
Connect a 4 inches round duct to adapter ring and sealing it with
waterproof tape.
Recover the ceiling.
5
6
Assemble the panel.
Please confirm whether the unit will be subjected to direct wind and
rain. If that is the case, a commercially available 4 inches rain cover
is recommended to be installed at the pipe outlet.
5-3
6
Plastic Anchor
Mounting
Hole
Mounting Hole Ø105mm
DN
DN
DN
DN
Installation Paper Mold
Ceiling
Round duct
External vent
Ceiling
WALL
WALL
INSTALLATIONS
INSTALLATIONS
CAUTION
INSTALLATIONS
CLEANING