8
BARBECUE GAS CONSUMPTION
TUCKER HORIZON BARBECUES ARE MADE
AND APPROVED TO AUSTRALIAN STANDARDS
A.G.A. Certificate Number 7932
SPECIFICATIONS
(In Mega Joules Per Hour)
Natural Gas
LPG:
Consumption
48mj/h
52mj/h
Natural Gas injector size 2.4mm Pressure 1KPA
Propane Gas injector size 1.5mm Pressure 2.75 KPA
For LP Gas connections, an approved 2.75 KPA
regulator and hose assembly connection to the
appliance is fitted by the manufacturer.
The appliance inlet is 3/8 S.A.E. male and is located
under the right hand side rear of the barbecue.
The minimum capacity propane cylinder for this
barbecue is 4 KG.
The intended use of this barbecue is to be installed
onto a Tucker cabinet stand.
Alternatively it may be set into brickwork or similar
non combustible surface.
Be sensible about the location of your barbecue.
The barbecue must be located on firm and level
ground.
Do not
locate the barbecue near combustible
materials or surfaces, either above or around the
barbecue.
Do not
obstruct any of the air ventilation openings
on the sides of the barbecue when installing
into brickwork, make sure to leave 200 square
centimeters minimum air ventilation underneath.
Warning in freezing conditions the pressure of
Propane gas can be reduced in the Cylinder
Tank causing a lack of gas pressure, this may
affect the way the barbecue operates.