Now we come to the last step - the Filter calibration in V/Octave
Information.
You need a frequency counter and a multimeter. Guitar tuner is also OK.
Procedure
1:)
You need
NO
signal input
2:)
set Resonancy to
MAX, Filter FM to left=0
3:)
set the filtermode to 24 dB – first line, fourth LED
4:)
connect a frequency counter to the VCF output ( usefull is our Filter Kalibrator4free )
5:)
Use only the '
CUT'
input for the calibration voltage .
6:)
calibration voltage is first 0 volt, adjust the resonance frequency with the Cutoff pot to 100
Hz.
7:)
now set the calibration voltage to 1 volt, the frequency must be double to 200 Hz
if not , adjust it with R11 to 200 Hz .
8:)
set now the voltage to 2 Volt , does the frequency counter shows 400 Hz ??
9:)
set the voltage to 3 Volt – now it must be 800 Hz .
Plus/minus a few HZ is OK.