LYDKRAFT ApS

 

 

Mose Allé 20, DK 2610 Rødovre 

 

Denmark 

7

 

ADJUSTMENT OF THE VU METER READING "COMPRESSION":

 

 
1) 

Turn the 

THRESHOLD

-control fully counter-clockwise. 

 
2) 

Switch the 

METER

-selector to Compression. 

 
3) 

Set the 

RATIO-

control at 2:1 

 
4) 

Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor. 

 
5) 

Adjust the 

GAIN-

control to an output-reading of 0,0 dBU. 

 
6) 

Adjust P 4 (P 2)* until the meter is reading 0 VU. 

 
7) 

Apply a DC-voltage of +250,0 mV into the side chain jack socket and observe that the 
output level has dropped to -10,0 dBU. If this is not the case, adjust the compression 
tracking (see above) 

 

Adjust P 3 until the meter is reading -10,0 VU. 

 
9) 

Remove the DC-voltage from the side chain jack socket. 

 
10) 

Repeat step 6 - 9.  

 
 
NB:  The VU-meter accuracy should be /- 0,5 dB when reading compression. 
 

ADJUSTMENT OF THE RELEASE CONTROL:

 

 
1) 

Set the 

METER

 switch in position compression. 

 
2) 

Set the 

attack/release SELECT

 switch in position manual. 

 
3) 

Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor. 

 
4) 

Adjust the 

THRESHOLD-

control to a reading of -10 VU of the    

VU-meter

 

 
5) 

Set the 

ATTACK-

control at fast. 

 
6) 

Set the 

RELEASE-

control at slow. 

 
7) 

Switch off the 1 kHz and observe that the VU meter moves to  0 VU in approx. 10 sec.  

 
8) 

If this is not the case, adjust P 1 (P 5)*, to obtain a release time of approximately 10 sec. 

 
 
 
 

The trimpots in parenthesis refers to PCB 870316-0,1,2 

 

(

950119) 

Содержание CL 1B

Страница 1: ...of both tubes valves are fed with a stabilized DC voltage The whole amplifier including input and output transformer and the power supplies are placed on one PC board Both input and output are balance...

Страница 2: ...he unit which performs the most compression is controlling the others To choose which one you want to control select the attack release time the threshold and the ratio on that unit and turn the thres...

Страница 3: ...o 40 dBU METER The VU meter switch has three positions 1 Input The meter is reading the level at the input socket 2 Compression The VU meter is reading gain reduction Its rest position is 0 VU and the...

Страница 4: ...ected release time takes over is dependent upon the setting of the attack control The more CW the attack control is turned the longer time before the selected release control takes over The more CCW t...

Страница 5: ...how much compression in dB we feel is needed for the various examples OVERALL COMPRESSION FINAL MIX COMPRESSION NEEDED 3 4 dB Attack release select Fix man Attack 2 o clock Release 10 o clock Ratio 9...

Страница 6: ...ply a signal of 1 kHz 30 0 dBU into the input of the compressor 2 Turn the GAIN control fully clockwise 3 Set the RATIO control at 2 1 4 Adjust the pre set GAIN located on amp psu PCB to an output rea...

Страница 7: ...above 8 Adjust P 3 until the meter is reading 10 0 VU 9 Remove the DC voltage from the side chain jack socket 10 Repeat step 6 9 NB The VU meter accuracy should be within 0 5 dB when reading compress...

Страница 8: ...LYDKRAFT ApS Mose All 20 DK 2610 R dovre Denmark 8 Over view of the sidechain PCB PCB 870316 0 1 2 P2 P3 P1 P5 0VU 10VU 10dB Rel 10 Sec PCB 870316 3 P4 P3 P2 P1 0VU 10VU 10dB Rel 10 Sec 101115...

Отзывы: