Tubbutec OrganDonor Siel Orchestra 1 Скачать руководство пользователя страница 7

Installing the switch contacts

As the switch boards are installed in reverse order switch 1 triggers the 
highest note and switch 49 triggers the lowest note. 

That also means that the key assignment is in reverse order. Keep that in
mind should you wish to play with the configuration!

Cut the ribbon cables to length and strip the wires.

Switch board 1

 (20pin connector):

Wires 1 (red stripe) gets soldered to the common bus bar, see picture.

Wires 2 gets cut.
Wires 3-18 get soldered to key contacts 49-34.
Wires 19 and 20 get cut.

Содержание OrganDonor Siel Orchestra 1

Страница 1: ...e Center punch Screw driver Included in the kit OrganDonor Main Board 4x OrganDonor Switch Board 1 single 2x16pin Connector 1x20 pin connector 1x 2pin connector Analog switch connection 1x20p 45cm 1x1...

Страница 2: ...rding to the schematics the Orchestra 1 is built similar to the 2 Maybe you have to adapt the placement of the switch boards but electrically it s the same as the Orchestra 2 Preparation After the fir...

Страница 3: ...he header on the top side of the board Solder the jumpers on the backside of the board as shown Switchboard 2 16pin Header make sure to install the header centered on the top side of the board Solder...

Страница 4: ...er make sure to install the header centered on the top side of the board Solder the jumpers on the backside of the board as shown Switchboard 4 Single Switch We already soldered the jumper on this boa...

Страница 5: ...everse order to keep cable length short From left to right Switch board 4 single switch board 3 16p switch board 2 16p switch board 1 20p main board Caution the case bottom is made out of plastic We r...

Страница 6: ...tors on the power supply pcb Remove the 4 screws holding the pcb Flip the pcb away from you so you have access to the bottom side Solder the wires of the power cable assembly as shown in the picture T...

Страница 7: ...at also means that the key assignment is in reverse order Keep that in mind should you wish to play with the configuration Cut the ribbon cables to length and strip the wires Switch board 1 20pin conn...

Страница 8: ...be installed on the back of the machine Use the provided drill guide to center punch the locations of the 3 holes The two small holes need to be about 3 2mmm to 3 5mm in diameter the large hole 15mm...

Страница 9: ...u need to flash the corresponding configuration file to OrganDonor using our configuration tool The configuration tool can also be used to experiment with settings and key assignments You ll find the...

Отзывы: