TTI FABRICATION ECOLO 50 Скачать руководство пользователя страница 9

SALT CHLORINATORS 

Salt chlorinators are made to be installed as inline chlorinators. Therefore, they must be installed as prescribed in the 
section above (“inline chlorinator or brominator”). 

 

PRESSURIZED CHLORINATOR OR BROMINATOR 

Pressurized chlorinators or brominators start by using a small quantity of water as it exits the filter, then add chemicals 

and  forward  this  highly  concentrated  solution  into  the  pool.  Check  valves  must  therefore  be  extremely  resistant  to 

corrosion. Only  use the valves that  have been supplied or  recommended by  the  manufacturer of your  chlorinator or 

brominator. 

 

 

 

 

 

 

 

CONNECTION TO ELECTRICAL POWER 

To  ensure  your  safety  and  the  proper  functioning  of  the  device,  the  electrical  connections  must  be  performed  by  a 

qualified electrician according to national codes, provincial and local regulations. 

 

A circuit breaker must be installed close to the heat pump, in an accessible location. 

 

Never open the electrical box without shutting off the power to all sources used for the operation of the heat pump. If 

your heat pump has a pool pump control option, remember to close the circuit breaker to this pump. 

 

The spec sheet for the heat pump contains all the requirements for voltage and amps. 

If the power cord is damaged, it must be replaced by a qualified electrician. 

 

 

 

 

 

Содержание ECOLO 50

Страница 1: ...ON MANUAL IMPORTANT It is important to register your product with us on our web site This will help us find your warranty when you place a service call If we cannot find your warranty registration a p...

Страница 2: ...Application 3 II Features 3 III Technical Parameters 4 IV Positioning 6 V Operation Instruction 10 VI Testing 12 VII Precautions 12 VIII Maintenance 13 IX Trouble shooting for common faults 13 X Failu...

Страница 3: ...uring operation E If the machine is stopped for a long time or in winter season please cut off the power supply and drain water clear of the machine by opening the tap of inlet pipe F Do not put your...

Страница 4: ...ir80 F water80 F 2 1 KW 2 7 KW 3 6 KW Heating current air80 F water95 F 9 5 A 11 4 A 15 9 A Heating power air80 F water95 F 2 4 KW 3 2 KW 4 3 KW Compressor RLA LRA 10 7A 57 5A 13 4A 75A 17 7A 90A Fan...

Страница 5: ...conditions 2 Related parameters are subject to adjustment periodically for technical improvement without further notice For details please refer to nameplate 3 Machine has heat function only Note The...

Страница 6: ...in front of the fan 120 cm 4 feet 4 in front of the service panel 120 cm 4 feet Objects should be placed as far away as possible from the area where air is evacuated OTHER RECOMMENDATIONS You should n...

Страница 7: ...nd installing this set of valves Fig A in order to be able to adjust the optimal water flow circulating in the heat exchanger condenser An adjustable automatic bypass valve must be installed when a wa...

Страница 8: ...BROMINATORS AND OTHER AUTOMATIC SYSTEMS BASIC CONNECTIONS INLINE CHLORINATOR OR BROMINATOR This connection is mandatory to ensure the long working life of your pool heat pump Any automatic distributio...

Страница 9: ...e manufacturer of your chlorinator or brominator CONNECTION TO ELECTRICAL POWER To ensure your safety and the proper functioning of the device the electrical connections must be performed by a qualifi...

Страница 10: ...r desired water temp c 5 seconds later the controller display will back to the normal mode d Switching between F and C hold for 10 seconds 3 Time setting a Available no matter whether the machine is o...

Страница 11: ...off When the indicator light is on and the time is flashing press again to set hour Use or to adjust before flashing stop press to set minute Use or to adjust After adjusting press and water temperatu...

Страница 12: ...for any abnormal noise from the machine VII Precautions 1 Attention A Set proper temperature in order to get comfortable water temperature to avoid overheating B Please don t stack substances that ca...

Страница 13: ...ff power supply to prevent any machine damage and cover the machine body with plastic foil to avoid dust C Please clean this machine with household detergents or clean water NEVER gasoline thinners or...

Страница 14: ...E 6 Compressor exhaust overload protection PP 1 Pool SPA heater sensor failure PP 2 Exhaust sensor failure PP 3 Coil pipe sensor failure PP 4 Intake pipe sensor failure PP 5 Air temp sensor failure PP...