TELECOMMUNICATIONS TECHNIQUES CORPORATION
49
Table 6-4
FIREBERD 6000 Asynchronous Test Set-Up With 188C
Step
Activity
1.
With the power to the FIREBERD 6000 turned OFF, insert the RS-449/530/MIL Data Interface in the designated rear-
panel slot.
2.
Press the POWER switch to apply power to the FIREBERD 6000.
RESULT:
The SETUP display shows the units current configuration.
NOTE:
If the FIREBERD 6000 is in Self-Loop mode after power-up, disengage the SELF LOOP switch.
3.
Set the DATA switch to the FOX data pattern.
4.
Set the GEN CLK switch to the SYNTH position for the FIREBERD to generate the clock.
5.
Set the TIMING MODE switch to the ASYNC position.
6.
Set the MENU switch to the SYNTH FREQ position. Set the synthesizer frequency to the desired baud rate.
7.
Set the MENU switch to the INTF SETUP position. Configure the RS449/530/MIL Data Interface as follows:
Select
1. MIL449 to select the RS-449/530/MIL Interface.
2. 188C to select the type of interface.
3. EMULATE to select DTE emulation.
4. SIGnaling to POSitive.
5. LL (Local Loop) and RL (Remote Loopback) ON or OFF depending on the test.
8.
Set the MENU switch to the CHAR FORMAT position. Select the desired asynchronous character format: DATA bits,
PARITY, and STOP bits.
9.
If a timed test is desired:
1. Set the MENU switch to TEST INTERVAL.
2. Press the MORE key twice, then press the TIMED softkey.
3. set the desired test length using the MENU keypad, then press the ENTER key.
4. Set the ANALYSIS MODE switch (located to the right of the RESULTS area) to SINGLE.
10.
If a continuous test is desired:
1. Set the MENU switch to TEST INTERVAL.
2. Set the desired measurement interval (default setting: 104), then press the ENTER key.
3. Set the ANALYSIS MODE switch (located to the right of the RESULTS area) to CONTINUOUS.
11.
If hard copy test results are desired, set the print event criteria using PRINT EVENT, then enable the printer control
block (located to the left of the POWER switch) by setting the OFF/ON switch to the ON position.
12.
Connect the FIREBERD 6000 to the equipment under test using the appropriate cables.
13.
Illuminate the RTS and DTR switches located just above the POWER switch to set both signaling leads to HIGH.
14.
If performing a loopback test, establish a loop by performing the procedures which are appropriate for your DCE.
15.
Check that the SYNC LED located at the upper right-hand corner of the FIREBERD 6000 is illuminated.
RESULT:
The FIREBERD has achieved pattern synchronization, and is gathering test results.